MODULE DIAGNOSTICS - 1 OF 2
MODULE STATUS DURING:
LED 2* LED 1** LED STATUS DIAGNOSTIC
MODULE PROGRAMMING
•
Flashing RED
Missing/wrong information from fi rmware or vehicle.
See fi rmware specifi c diagnostics, or contact technical support.
•
Solid RED Module waiting for more vehicle information. Programming incomplete.
•
Flashing GREEN Additional steps required to complete programming. Refer to install guide.
•
Solid GREEN then OFF Module programming completed successfully.
o
OFF No activity or module already programmed.
•
1 RED fl ash No fi rmware on module. Connect to Weblink and fl ash device.
•
2 ORANGE fl ashes Contact technical support.
•
3 ORANGE fl ashes Module programming not completed.
•
4 ORANGE fl ashes Contact technical support.
•
7 ORANGE fl ashes Contact technical support.
•
8 ORANGE fl ashes Loop not cut. Ensure loop is cut for automatic transmission. Reset and re-learn.
•
9 ORANGE fl ashes Loop not cut. Ensure loop is cut for automatic transmission. Reset and re-learn.
•
10 ORANGE fl ashes Boot loader update failed. Contact technical support.
•
11 ORANGE fl ashes T-harness detection does not match install type selection in Weblink.
TACH PROGRAMMING
•
Solid RED Tach learn in progress.
•
1 GREEN fl ash Tach signal programmed in analog.
•
2 GREEN fl ashes Tach signal programmed in data.
•
3 RED fl ashes No tach signal detected
•
4 RED fl ashes System is in valet mode. Turn off valet mode to program tach.
•
6 RED fl ashes Engine sensing set for ‘assumed start’. No tach programming required.
•
7 ORANGE fl ashes Engine sensing not confi gured properly. Contact technical support.
* LED 2 (RS) displays generic diagnostic codes specifi c to the remote start module. Orange LED fl ashes may appear red.
** LED 1 (Bypass) displays diagnostic codes specifi c to the fi rmware loaded on the module.
Visit the programming diagnostics page for more information.