How to free up memory on Fluke 2638A?
- DDavid HoffmanJul 27, 2025
If your Fluke Data Logger is out of memory, it means that either the internal memory or the USB drive is full. To resolve this, delete or transfer files to free up space.
How to free up memory on Fluke 2638A?
If your Fluke Data Logger is out of memory, it means that either the internal memory or the USB drive is full. To resolve this, delete or transfer files to free up space.
How to fix a Fluke Data Loggers that won't turn on?
If your Fluke Data Logger doesn't power on, first ensure the power cord is correctly plugged into both the device and the power outlet. Verify that the outlet is active. Also, make sure that the power entry setting on the device matches the AC mains power supply rate. Finally, inspect the fuse; if it's blown, replace it with one of the same rating, voltage, and type. If it blows again, a component failure is likely.
What to do if my Fluke Data Loggers display is blank?
If your Fluke Data Logger display is blank but the LED lights are on, first check if the unit is in standby mode (amber power LED). If so, press the Standby key on the front panel to exit. Also, check if the screen saver is activated by pressing any front panel key. If neither of these resolves the issue, the screen or unit may be malfunctioning, and you should contact Fluke Calibration.
Why is my Fluke 2638A not recording when I start a scan?
If your Fluke Data Logger does not record when you start a scan, the Auto Recording feature may not be enabled. You can either manually start recording or enable Auto Recording in the test setup.
What to do if my Fluke 2638A cannot read a USB drive?
If your Fluke Data Logger cannot read the USB drive, ensure the USB drive is fully inserted; the LED should light up within 30 seconds. If the LED is always illuminated, even without the USB drive, the USB driver may be locked. Cycle the power using the main power switch and reinsert the USB drive. If the problem persists, try replacing the USB drive.
Why won't my Fluke Data Loggers start scanning?
If the Fluke Data Logger does not start scanning after you initiate a scan, the device may be waiting for a trigger. Verify the trigger type in the test setup and ensure it is correctly configured.
What to do if Fluke 2638A Data Loggers input module is not recognized?
If the Input Module is not recognized by your Fluke Data Logger, first reinstall the Input Module, ensuring it is fully seated in the slot. Also, check that the relay card is installed. If the issue persists, contact an Authorized Customer Service Center.
Explains symbols, defines warnings/cautions, and details the screen capture feature.
Details scan rate, voltage, current, frequency, resistance, sensor, and digital I/O measurements.
Explains channel numbering, basic operations, and setting channels ON/OFF.
Details configuration for voltage, current, resistance, sensors, DIO, totalizer, and math channels.
Helps diagnose and solve common product problems with causes and solutions.
Explains symbols, defines warnings/cautions, and details the screen capture feature.
Details scan rate, voltage, current, frequency, resistance, sensor, and digital I/O measurements.
Explains channel numbering, basic operations, and setting channels ON/OFF.
Details configuration for voltage, current, resistance, sensors, DIO, totalizer, and math channels.
Helps diagnose and solve common product problems with causes and solutions.
| Resistance Range | 0 to 100 MΩ |
|---|---|
| Power Supply | 100 V to 240 V AC, 50 Hz to 60 Hz |
| Voltage Range | ±300 V |
| Resolution | 6.5 digits |
| Memory | USB |
| Interface | USB, Ethernet |
| Display | Color |
| Measurement Types | DC voltage, AC voltage, resistance, DC current, AC current, frequency, temperature |