3. Do not use the trimmer if the electric cables are dam-
aged or worn.
4. Immediately disconnect from the mains electricity supply
if the cable is cut, or the insulation is damaged. Do not
touch the electric cable until the electrical supply has
been disconnected. Do not repair a cut or damaged
cable. Replace it with a new one.
5. Your extension cable must be uncoiled, coiled cables
can overheat and reduce the efficiency of your trimmer.
6. Keep the cable clear of the cutting area and obstacles
at all times.
7. Do not pull cable around sharp objects.
8. Always switch off at the mains before disconnecting
any plug, cable connector or extension cable.
9. Never pull on the cable to disconnect any of the plugs.
10.Switch off, remove plug from mains and examine
electric supply cable for damage or ageing before
winding cable for storage. Do not repair a damaged
cable, replace it with a new one. Use only our re-
placement cable.
11.Always wind cable carefully, avoiding kinking.
12.Use only on AC mains supply voltage shown on the
product rating label.
13.Our trimmers are double insulated to EN60335.
Under no circumstance should an earth be connected
to any part of the trimmer.
Preparation
1. While using your product always wear substantial
footwear and long trousers.
2. Before using the machine and after any impact, check
for signs of wear or damage and repair as necessary.
3. Inspect the area to be cut before each use. Remove
all objects such as stones, broken glass, nails, wire,
string etc, which can be thrown or become entangled
in the trimmer head.
4 . Before use, inspect the area for wildlife, especially
hedgehogs.
5. Check that the cutting head is fitted correctly.
Use
1. Use the trimmer only in daylight or good artificial light.
2. Avoid operating your trimmer in wet grass, where feasible.
3. Take care in wet grass, you may lose your footing.
4. On slopes, be extra careful of your footing and wear
non-slip footwear.
5. Do not walk backwards when trimming, you could trip.
Walk never run.
6. Keep cutting head below waist level.
7. Switch off before pushing the trimmer over surfaces
other than grass.
8. Never operate the trimmer with damaged guards or
without guards in place.
9. Never fit metal cutting elements.
10.Keep hands and feet away from the cutting means at
all times and especially when switching on the motor.
11.Never pick up or carry a trimmer by the cable.
12.Do not lean over the trimmer guard - objects may be
thrown by the cutting line.
13.Remove the plug from the mains :
- before leaving the trimmer unattended for any period;
- before clearing a blockage;
- before checking, cleaning or working on the appliance;
- if you hit an object. Do not use your trimmer until you
are sure that the entire trimmer is in a safe operating
condition;
- if the trimmer starts to vibrate abnormally. Check im-
mediately. Excessive vibration can cause injury.
Maintenance and storage
1. Keep all nuts, bolts and screws tight to be sure the
trimmer is in safe working condition.
2. Replace worn or damaged parts for safety.
3. Only use the replacement cutting line specified for
this product.
4. Only use replacement parts and accessories recom-
mended by Husqvarna UK Ltd.
5. After any maintenance in dealing with the cutting line, al-
ways return the product to its normal operating position
before switching on.
6. Clean unit with a dry cloth. Never use metal objects to
clean the unit.
7. Inspect and maintain the trimmer regularly. Any repairs
must be carried out by an authorised repairer.
8. Store in a cool dry place and out of reach of children.
Do not store outdoors.
9. Allow the product to cool for at least 30 minutes be-
fore storing.
Cables
IMPORTANT
Use only 1.00mm
2
size cable up to 40 metres length maximum.
Maximum rating:
1.00mm
2
size cable, 10 amps 250 volts AC.
YOUR TRIMMER IS SUPPLIED WITH AN ELECTRIC
MAINS CABLE WIRED DIRECTLY INTO THE PROD-
UCT.
1.Mains Cables and Extension Cables are available from
your local Approved Service Centre.
2.Do not wire an extension cable directly to your product your-
self. Please contact your local Approved Service Centre for
further information on the connectors and kits available.
3.Only use extension cables specifically designed for
outdoor use.
4.If the supply cable is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
CONNECTORS
Our connectors are suitable for use with 2 core cable
only. Under no circumstances should these connectors
be used for earthed products.
All of our connectors and cables are of splashproof con-
struction. They are not waterproof and must not be left
outside permanently nor should they be submerged or
immersed in water. Do not let cable lay or trail through
pools of water or splashed with water from hose pipes.
MAINS PLUG REPLACEMENT
If the plug supplied is cut off it should be destroyed.
There is an electric shock hazard if a cut off plug is in-
serted into a 13 amp socket.
1. No earth required. Our products are double insulated
to EN60335 and under no circumstances should an
earth be connected to any part of the product.
2. Ensure the mains voltage suits your
pr
oduct.
3. IMPORTANT!
The wires in the mains lead are coloured in accordance
with the following code:
BLUE - NEUTRAL
BROWN - LIVE
The wire which is coloured BLUE must be connected to
the Terminal which is marked with the letter ‘N’ or
coloured BLACK. The wire which is coloured BROWN
must be connected to the Terminal which is marked with
the letter ‘L’ or coloured RED.
4. It is important that the outer sheath is clamped cor-
rectly into the 3-pin plug.
5. If in doubt consult your local Service Repairer or qual-
ified electrician before the machine is used.
6. A 13 Amp fuse must be fitted to the Mains Plug.
7. The normal plug fuse and household fuse only pro-
tect the electrical equipment and are not a safeguard
against electrocution.
If your product is hard wired i.e. non-detachable mains
electric cable, a conversion kit and extension cable is
available from all Approved Service Centres which can
be found in your local Yellow Pages.

Other manuals for Flymo MINI TRIM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flymo MINI TRIM and is the answer not in the manual?

Flymo MINI TRIM Specifications

General IconGeneral
BrandFlymo
ModelMINI TRIM
CategoryTrimmer
LanguageEnglish

Related product manuals