EasyManuals Logo
Home>Ford>Portable Generator>FG5250PBE

Ford FG5250PBE User Manual

Ford FG5250PBE
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12
OPERATION
Never handle the generator, electronic devices, or any cord while standing in water, while barefoot, or when hands or
feet are wet.
Always keep the generator dry. Never operate generator in rain or under wet conditions.
Use a ground fault circuit interrupter (GFCI) in a damp or highly conductive area, such as metal decking or steel
work.
Never plug electronic devices into generator having frayed, worn, or bare wires. Never touch bare wires or make
Never permit a child or unqualified person to operate generator. Keep children a minimum of 10 feet away from the
contact with receptacles.
generator at all times.
If using the generator for back up power, notify the utility company.
If connecting generator to a building’s electrical system for standby power, you must use a qualified electrician to
install a transfer switch. Failure to isolate the generator from the power utility could result in serious injury or death to
electric utility workers.
WARNING!
This generator produces a very high voltage which could result in burn or
electrocution causing serious injury or death.
Connecting Generator to an Electrical System
a transfer switch. The power from the generator must be isolated from the circuit breaker or alternative power source.
If connecting generator to a building’s electrical system for standby power, you must use a qualified electrician to install
The connection must comply with all electrical codes and applicable laws.
Fig 7Fig 6
Unleaded
Gasoline
10W30 OIL
Grounding the Generator (See fig 8)
The ground terminal located on the back of the generator frame must always be used
to connect generator to a driven ground rod. Connect the ground terminal to the driven
ground rod with a No 8 AWG (American Wire Gauge) copper wire. The wire connects
to the terminal between the lock washer and nut. Tighten the nut securely to ensure
proper connection. Grounding the generator protects you from electric shock that
results from a build up of static electricity or undetected ground faults.
Fig 8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ford FG5250PBE and is the answer not in the manual?

Ford FG5250PBE Specifications

General IconGeneral
BrandFord
ModelFG5250PBE
CategoryPortable Generator
LanguageEnglish