is of too low temperature.
water ranges between 8℃
and 25℃.
The ice-making cycle
seems normal but no
ice is produced.
The ambient temperature or
water temperature is too high.
Start the ice-making cycle at
a environment with an
ambient temperature less
than 32
°
C and fill the
water reservoir with some
cold water.
Refrigerating system leaks
Refrigerating system blocks
1.Poor heat dissipation.
2.The water temperature is too
3.The ambient temperature is too
1. Leave a 6-inch clearance
on all sides of the ice maker
for proper ventilation.
2. Fill the water reservoir
with water ranges between
8
℃
and 28
℃
.
3. Operate the ice maker at
a environment with an
ambient temperature
between 10
℃
and 32
℃
.
Model:
Applicable climate:
Class:
Power source:
Rated power:
EFIC123-B-SSRED/EFIC108-B-RED/EFIC123-B-SS/EFIC123-B-SSBLACK
ST/SN/N/T
I
120V/60Hz
105W
Refrigerant/Refrigerant amount: R600a / 23g
Foaming agent: C
5
H
10
Net weight: 7. 7 kg
Ice marking amount per time: 9pcs.
Ice-dispensing time: 8mins (depends on the ambient temperature and water temperature).
Daily ice output: 12Kg/24H
Housing: PP
Unit size(DXWXH): 310*230*325mm