En-4
Fog comes out of the indoor unit:
During Cooling operation, a thin mist may be seen emitted from the
indoor unit. This results from the sudden Cooling of room air by the air
emitted from the air conditioner, resulting in condensation and mist-
ing.
Steam comes out of the indoor unit:
During Heating operation, the outdoor unit’s fan may stop, and steam
may be seen rising from the unit. This is due to the Automatic Defrost-
ing operation. (See page 2)
Water is produced from the outdoor unit:
During Heating operation, water may be produced from the outdoor
unit due to the Automatic Defrosting operation.
The following conditions may not be breakdowns so
check again.
Doesn’t operate at all:
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the main power switch set to the OFF position?
Are you trying to engage in an operation different from the priority
state? (See page 2)
Is it in standby state? (See page 2)
The operation mode cannot be changed:
Are you trying to change to an operation different from the priority
conditions? (See page 2)
Poor Cooling (or Heating) performance:
Did you adjust the room temperature settings (thermostat) correctly?
Is the air lter dirty? (See page 2)
Are the air conditioner’s inlet port or outlet port blocked?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sunlight to
enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?
Is the fan speed set to low?
Set the temperature lower than the room temperature and use it:
Temperature does not fall down well. Temperature may not fall down
depending on the room conditions. (While high humidity or the room
temperature is high.) (See page 2)
In the following situations stop operation immediately
and get in touch with authorized service personnel.
The problem cannot be solved even when the troubleshooting checks
have been performed.
The FILTER indicator lamp (red) is ashing very fast.
The wired remote controller or simple remote controller indicate Er
(when connected).
It has burning smell.
SPECIFICATIONS
MODEL
AUXB
004
GLEH
AUXB
007
GLEH
AUXB
009
GLEH
AUXB
012
GLEH
AUXB
014
GLEH
AUXB
018
GLEH
AUXB
024
GLEH
POWER SOURCE 230 V ~ 50/60 Hz
AVAILABLE VOLT
-
AGE RANGE
198 to 264 V (50Hz) , 198 to 253 V (60Hz)
COOLING
CAPACITY
[kW] 1.1 2.2 2.8 3.6 4.5 5.6 7.1
[BTU/h]
3,800 7,500 9,600
12,300 15,400 19,100 24,200
HEATING
CAPACITY
[kW] 1.3 2.8 3.2 4.1 5.0 6.3 8.0
[BTU/h]
4,400 9,600
10,900 14,000 17,100 21,500 27,300
INPUT
POWER
[W] 23 25 25 29 35
36 84
CURRENT [A] 0.17 0.17 0.17 0.20 0.24 0.25 0.62
SOUND PRESSURE LEVEL (COOLING/HEATING)
HIGH dB [A] 34/34 34/34 35/35 37/37 38/38 41/41 50/50
MED -
HIGH
dB [A] 32/31 32/32 33/33 34/34 37/37 39/39 46/46
MED dB [A] 30/29 30/30 31/31 33/33 34/34 36/36 43/43
MED -
LOW
dB [A] 28/26 28/28 29/29 31/31 32/32 33/33 39/39
LOW dB [A] 27/24 27/27 27/27 29/29 30/30 30/30 35/35
QUIET dB [A] 25/21 25/25 25/25 27/27 27/27 27/27 30/30
DIMENSIONS & WEIGHT
HEIGHT [mm] 245
WIDTH [mm] 570
DEPTH [mm] 570
WEIGHT [kg]
14.5 15 17
9369313325-01_OM.indb 4 2/7/2019 18:29:02

Other manuals for Fujitsu AIRSTAGE AUXB004GLEH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AIRSTAGE AUXB004GLEH and is the answer not in the manual?

Fujitsu AIRSTAGE AUXB004GLEH Specifications

General IconGeneral
BrandFujitsu
ModelAIRSTAGE AUXB004GLEH
CategoryAir Conditioner
LanguageEnglish

Related product manuals