Type Inverter heat pump
Model name AOYG36KBTB AOYG45KBTB
Power supply 230 V ~ 50 Hz
Power supply intake Outdoor unit
Available voltage range 198—264 V
Starting current A 13.0 18.6
Fan
Airflow rate
Cooling
m
3
/h
3,750 4,450
Heating 3,750 4,450
Type × Q'ty Propeller × 1
Motor output W 100 120
Sound pressure level *1
Cooling
dB (A)
55 57
Heating 55 57
Sound power level
Cooling
dB (A)
70 71
Heating 70 71
Heat exchanger type
Dimensions
(H × W × D)
mm
Main1: 756 × 905 × 18.19
Main2: 756 × 905 × 18.19
Main1: 966 × 905 × 18.19
Main2: 966 × 905 × 18.19
Sub: 966 × 543 × 18.19
Fin pitch 1.45
Rows × Stages 1 × 36 1 × 46
Pipe type Copper
Fin
Type (Material) Aluminum
Surface treatment Blue fin
Compressor
Type × Q'ty DC Twin rotary × 1
Motor output W 1,500 2,180
Refrigerant
Type (Global warming potential) R32 (675)
Factory charge g 1,900 2,700
Refrigerant oil
Type FW68D RmM68AF
Amount
cm
3
600 800
Enclosure
Material Steel sheet
Color
Beige
Approximate color of Munsell 10YR 7.5/1.0
Dimensions
(H × W × D)
Net
mm
788 × 940 × 320 998 × 940 × 320
Gross 966 × 1,027 × 445 1,176 × 1,027 × 445
Weight
Net
kg
52 67
Gross 60 75
Connection pipe
Size
Liquid
mm (in)
Ø9.52 (Ø3/8)
Gas Ø15.88 (Ø5/8)
Method Flare
Pre-charge length
m
30
Max. length 50
Max. height difference 30
Operation range
Cooling
°C
-15 to 46
Heating -15 to 24
Drain hose
Material LDPE
Tip diameter mm Ø13.0 (I. D.), Ø16.0 to Ø16.7 (O. D.)
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*1: Sound pressure level
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
This data is based on EN 14511 standard.
- 64 -
1. Specifications
OUTDOOR UNIT
AOYG18-45KBTB
OUTDOOR UNIT
AOYG18-45KBTB

Table of Contents

Other manuals for Fujitsu ARXG22KMLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARXG22KMLA and is the answer not in the manual?

Fujitsu ARXG22KMLA Specifications

General IconGeneral
BrandFujitsu
ModelARXG22KMLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals