EasyManuals Logo
Home>Fujitsu>Air Conditioner>ARXG45KMLA

Fujitsu ARXG45KMLA User Manual

Fujitsu ARXG45KMLA
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
4-4. Indoor unit fan motor
¢ Models: ARXG36KMLA and ARXG45KMLA
WARNING
→hen you approach this part, please cut off the power supply and wait for a while until DC voltage
has been discharged.
Check point 1. Check rotation of fan
Rotate the fan by hand when operation is off.
(Check if fan is caught, dropped off or locked motor)
 If fan or bearing is abnormal, replace it.
Check point 2. Check resistance of indoor fan motor
Refer to below. Circuit-test “Vm” and “GND” terminal
NOTE: Vm: DC voltage, GND: Earth terminal
 If they are short-circuited (below 300 kΩ), replace indoor fan motor and controller PCB.
Pin number
(wire color)
Terminal function
(symbol)
1 DC voltage
4 Earth terminal
1 (Red) DC voltage (Vm)
2 No function
3 No function
4 (Black) Earth terminal (GND)
5 (→hite) Control voltage (Vcc)
6 (Yellow) Speed command (Vsp)
7 (Brown) Feed back (FG)
4-4. Indoor unit fan motor - (03-54) - 4. Service parts information
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Other manuals for Fujitsu ARXG45KMLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARXG45KMLA and is the answer not in the manual?

Fujitsu ARXG45KMLA Specifications

General IconGeneral
BrandFujitsu
ModelARXG45KMLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals