27
9RLFCC
Heat Pump
12RLFCC
Heat Pump
18RLFCC
Heat Pump
9,000 12,000 18,000
3,100~12,000 3,100~13,600 3,100~20,100
12,000 16,000 21,600
3,100~18,000 3,100~19,400 3,100~25,600
13.0 12.2 11.5
24.0 21.9 20.1
14.5/13.5 12.8/11.1 11.2/12.3
14~115 (-10~46) 14~115 (-10~46) 14~115 (-10~46)
-5~75 (-21~24) -5~75 (-21~24) -5~75 (-21~24)
1.3 (.06) 2.5 (1.2) 4.6 (2.2)
208-230/60/1 208-230/60/1 208-230/60/1
15 15 20
318 (540)
Clg or Htg
359 (610)
Clg or Htg
400 (680) Clg
471 (800) Htg
288 (490)
Clg or Htg
312 (530)
Clg or Htg
341 (580) Clg
400 (680) Htg
259 (440)
Clg or Htg
277 (470)
Clg or Htg
288 (490) Clg
341 (580) Htg
230 (390)
Clg or Htg
241 (410)
Clg or Htg
241 (410) Clg
265 (450) Htg
33/34 37/37 40/44
32/32 33/33 36/40
29/29 31/31 32/36
28/27 28/28 28/30
590/720 870/780 1,050/1,000
48/49 49/50 54/55
3.0 4.4 7.1
4.1 6.7 7.7
0.62/1.40 0.94/1.45 1.61/2.15
0.89/1.80 1.44/2.00 1.76/2.60
4+auto 4+auto 4+auto
Automatic Automatic Automatic
Washable Washable Washable
UTG-CCGF* UTG-CCGF* UTG-CCGF*
Flare Flare Flare
suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4
9 (2.7) 9 (2.7) 9 (2.7)
66 (20)
(pre-charge: 49’)
66 (20)
(pre-charge: 49’)
66 (20)
(pre-charge: 49’)
49 (15) 49 (15) 49 (15)
33 (15) 33 (15) 33 (15)
84 (38) 84 (38) 86 (39)
9-11/16 (245) 9-11/16 (245) 9-11/16 (245)
22-7/16 (570) 22-7/16 (570) 22-7/16 (570)
22-7/16 (570) 22-7/16 (570) 22-7/16 (570)
1-15/16 (49) 1-15/16 (49) 1-15/16 (49)
27-9/16 (700) 27-9/16 (700) 27-9/16 (700)
27-9/16 (700) 27-9/16 (700) 27-9/16 (700)
24-1/2 (620) 24-1/2 (620) 24-1/2 (620)
31-3/32 (790) 31-3/32 (790) 31-3/32 (790)
11-11/32 (290) 11-11/32 (290) 11-11/32 (290)
R410A R410A R410A
Nominal Cooling
BTU/h
Min~Max Cooling
BTU/h
Nominal Heating
BTU/h
Min~Max Heating
BTU/h
HSPF
SEER
EER
Clg/Htg
Cooling Operating Range °F(°C)
Heating Operating Range °F(°C)
Moisture Removal
Pt./h(l/h)
Voltage/Frequency/Phase
Recommended Fuse Size
(A)
Air Circ.
C.F.M. (m
3
/h)
: Hi
Medium
Low
Quiet
Noise Level
dB(A) Clg/Htg
: Hi
Medium
Low
Quiet
Outdoor Fan Speed
RPM Clg/Htg
Outdoor Noise Level
Clg/Htg
Running Current
Rated
(A)
: Cooling
Heating
Power Use
Rated/Max
(kW)
: Clg
Heating
Fan Speeds Stage
Air Direction: Vertical
Air Filter
Front Grille
Connection Method
Conn. Pipe Diameter
Inch
Combined Min. Length
Ft (m)
Combined Max. Length
Ft (m)
Max. Vertical Diff.
Ft (m)
Indoor Unit Net Weight
lbs.
(kg)
Outdoor Unit Net Weight lbs.
(kg)
Indoor Unit Dim: Height
Inch (mm)
Width
Inch (mm)
Depth
Inch (mm)
Grille Dim: Height
Inch (mm)
Width
Inch (mm)
Depth
Inch (mm)
Outdoor Unit Dim: Height
Inch (mm)
Width
Inch (mm)
Depth
Inch (mm)
Refrigerant
Note: Figures are based on 230 Volts.
22.5”
22.5”
Easy Installation
Fits into a standard ceiling tile*.
*Dimensions of outer grille are 27-9/16” x 27-9/16”
and may overlap adjacent tiles.
2-Stage Turbo Fan
Air distribution is evenly spread across
the heat exchanger by the 2 stage turbo
fan which produces two separate airflow
streams.
Heat exchange
efficiency:
Increased 20%
1-stage
2-stage
Quiet Operation
Optimization of wing form (laminar wing
design) and number of wings (7 blades)
enables as low as 27 dB.
Systems 9RLFCC, 12RLFCC
* Compact Cassette Grille UTG-CCGF sold separately.
Must order one with each compact cassette.