9
2.2 Wiring
2.2.1 Junction box (for FELCOM 16)
Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16. Unfasten
four screws to remove the cover to connect cables to terminal board. For detailed wiring
information see the interconnection diagram.
For connection, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view
of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV-SB-C 0.2x5P
cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with the
junction box.
Cover
Terminal
board
Communication
Unit
Procedure
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
Core 7 mm
1
2
3
Vcc
GND
TD/RD-A
TD/RD-B
NC
TD-A(NAV)
TD-B(NAV)
RD-A(NAV)
RD-B(NAV)
GND
DMC OUT-H
DMC OUT-C
DMC IN-H
DMC IN-C
DMC CTR
IC-305/306
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Cable clamp
(top)
Note 1: Do not insert the cable too
deeply, to prevent pinching the sheath.
Note 2: Pull each cable slightly to con-
firm that they are in their holes securely.
90mm15mm 7mm
16S0344
Fold back braided shield onto
sheath and fix by cable clamp.
Cable clamp
Cable clamp
(bottom)
Junction box IC-315