Technical Data Sheet - 225-300kVA UL Listed
Energy
Digital Energy
Standard :
Optional :
Communication
Mimic Diagram
Alarm LED
RPA, IEMi
eBoost™ (Patented) Operating Mode
RPA Cable Saver Inductor
FCC Filter
Dual Input
Input/Output Transformers
External Maintenance Bypass
Remote Status Panel
Protection Software
SNMP Communication
RS-232 / SNMP / MODBUS
Display of UPS metering functions , event history, configuration of
parameters and helps perform critical UPS Operations
Bar graph status indicator on Home Page of LCD
-Inverter On
-Total Off with protective cover
-Ethernet interface for network connection
-Available in external or as a part of output switchgear cabinet
Load level in %, Battery run time in min.
-Available in external cabinets for isolation or voltage transformation
-Integral to UPS cabinet. No additional cabinet required
Optional Features
-Simplify Parallel Systems installation & Improve current sharing
-Inverter Off
-Active mimic diagram w/ Stop Operation and Summary Alarms
6 user defined contacts (form 'C') (1A / 24V DC)
12 user defined contacts (form 'C') (1A / 24V DC)
Represents operational status of the UPS on Home Page of LCD
Visual (LED) and audible signal, activates approx. 3 minutes
(adjustable) before complete and automatic load shutdown due to the
battery is fully discharged and the load cannot be transferred on
utility or Over temperature or overload condition (>125%) and the load
cannot be transferred on utility.
Front Panel Controls, Signals & Alarms
(23 selectable signals include aux. Inputs 1 & 2)
Visual (LED) when load is on inverter OR load is on bypass
Visual (LED) and audible signal active when any alarm condition is
present
Multilanguage Graphic LCD
Push Buttons
Load Level / Battery Run Time
Warning LED
BLINK when alarm is active and not acknowledged
Input signals
Emergency Power Off (user supplied N.C. contact)
Aux. input 1 * (default = On Generator)
Aux. input 2 * (configurable)
Operation LED
-Redundant Parallel Operation, Intelligent Energy Management
Integrated
BLINK during service check
External Interface
-Brings UPS into compliance with FCC, Class A Specifications
Alarm contacts (voltage-free)
* Status displayed on LCD panel
-PC operated remote monitoring, control and diagnostics
Supports 14 Languages(Chinese, Czech, Dutch, English, Espanola,
Francais, German, Italiano, Polish, Portuguese, Russian, Slovensko,
Soumi, Swedish)
-High Efficiency Operating Mode for Single and Multi module
applications
g
imagination at work
GEA-D2041 (225 300kVA TDS), Page: 4