About the water softener system.
Service: Electronic Demand Time Features and Service
ERRORCODE
DISPLAYED ERR03 ERR04 ERR05
POSSIBLEDEFECT • Control
ERR01
• Motor
inoperative
• Wiring
harness or
connection
to switch
• Position
switch
• Control
ERR02
• Position
switch
•Control
• Motor
inoperative
or wiring
harness
•Control
• Position
switch or
wiring
harness
• Control
Toremove an error code: 1. Unplug transformer.
Z Correct defect.
& Plug transformer in.
4. Wait for ot leost 6 minutes. Theerror codewill return if the reasonfor
theerror code was not corrected.
Service: Timer/Softener, Service Checkout Procedure
If gou are not getting soft water, and an error
code is not displaced, usethe procedures below
to find the problem. First make the following
visual checks.
VISUAL CHECKS:
1.Is there electrical power to the outlet the water
softening sgstem transformer is plugged into?
Z Isthere sufficient salt in the storage tank?
3. Isthe softener bypass valve directing water
for soft water service?
4. Is the valve drain hose open to the drain,
not more than 8' above the softener, and
unobstructed? If hose is above 8', see
page 8, step 4.
tf bloudo not find a problem with the visual
checks, continue below.
CONTROL SHOWS
WRONG TIME AND
DAY,AND/OR IS
FLASHING.
CONTROL
DISPLAY
BLANK.
Checkelectrical
power to control
.._ (outlet,
transformer,
power cable,all
connections).
INO POWERI.__. REPAIRAS
NEEDED
"-_"C POWER OK--_- I CONTROL
DEFECTIVE
Electricalpower was I Investigate reason for
off. Resetthe correct _ Ipower oss.
time of dag.
Domanual
diagnostics
to verifg
i proper
function.
CONTROL DISPLAY
SHOWS CORRECTTIME
AND DAY AND IS
STEADY.
Domanual
diagnostics.
16