Place the blower unit back into the opening.
Locate the two “knockout” plates, on the rear
oven panel, near the top of the oven.
Using tin snips, carefully cut the web area from
the two holes side-by-side (that secure the
knockouts to the oven). Cut all four webs on
both rear knockouts; this will allow the
ventilation fan airflow to exhaust out the
rear of the oven.
CAUTION: Be sure to trim the sharp edges from
the openings after removing the knockout plates.
Roll the blower unit 90° so that fan blade
openings are facing out the back of the
oven.
4
Snip all 4 webs
on each knockout
panel and remove
the metal knockouts
for rear airflow.
BEFORE: Fan Blade
Openings Facing Up
AFTER: Fan
Blade Openings
Facing Back
2
1
Remove the two screws that hold the blower plate
and remove the screw holding the blower motor
to the oven. Slide blower plate from under its
retaining flange.
ADAPTING BLOWER FOR
OUTSIDE BACK EXHAUST
B5.
17
Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust
the blower unit.
Blower Plate
Blower Plate
Replace the blower plate in the same position
as before and replace the screws for the
blower plate and blower motor.
Before Rolling
After Rolling
Back of Oven
Back of
Oven
Back of
Oven
CAUTION: Do not pull or stretch the blower
unit wiring. Make sure the wires are not pinched.
NOTE: The blower unit exhaust openings should
match exhaust openings on rear of oven.
Installation Instructions
Retaining
Flange
Blower Plate Screws
Oven Rear Panel
Back of
Oven
3
Rotate blower unit counterclockwise 180°.
Before Rotation After Rotation
Back of
Oven
Back of
Oven
5
6
7
Blower Motor Screw