NX-148E LCD Keypad
24
DISPLAY DESCRIPTION
Cancel
Cancel System is disarmed and the Cancel button was
pressed within 5 minutes of an alarm.
Gnd Flt
Ground Fault A short to ground has been detected.
Man Test
Manual Test Bell and/or communicator test while system is in
disarmed condition.
Re-exit
Re-Exit The exit delay has been re-started without
disarming the system.
Output Trip
Output Trip A trip has occurred on an expander auxiliary
output.
Data Lost
Data Lost Communication of a signal has failed (log only
event).
Walk-test
Walk-Test A zone “Walk-Test” mode has been activated.
End Test
End Test Test has been ended.
Cross-Trip
Cross Trip The first zone of a cross zone has been tripped
(log only).
Expansion
Event
Expansion
Event
An expansion module created an undefined
event.
Partial Arm
Partial Arm Reports a closing in the stay mode.
Listen In
Listen In A listen in function has been activated.
Service Start
Service Start Technician is on site.
Service End
Service End Technician is off site.
Code Entry
Code Entry A code has been entered.
First Open
First Open Reports when the first partition is disarmed.
Last Close
Last Close Reports when the last partition is armed.
Sprnklr
Sprinkler Instant sprinkler supervisory report
Clock Set
Clock Set Clock has been reset.
RF Jammed
RF Jammed A wireless expansion module is jammed
CleanMe
CleanMe A smoke detector requires cleaning.