Performance Data Sheet
Model GERPWFE
UseReplacement Cartridge RPWFE.
Theconcentration of the indicated substances in water entering the system was reduced to a concentration lessthan or equal to the permissible
limit for water leaving the system as specified in NSF/ANSIStandard 42 and Standard 53.Systemtested and certified by NSFInternational against
NSF/ANSIStandard 42 and Standard 53for the reduction of substances listed below.
170 Gallons (643.5 Liters}.
for Reduction AverageInfluent
2.0 mg/L
Contaminant Reduction Determined NSF testinc
AveragePr0duct I Max Permissible
Water Product Water
Challenge Concentration Reduction Concentration Concentration Requirements
2.0 mg/L ± 10% 97.4% 0.05 mg/L N/A _>50%
Test Report
J-00!02044
7,633,333 pts/mL At least 10,000 particles/mL 99.0% 71,850 pts/ml N/A _>85% J-00!06249
107to 10sfibers/L; fibers
109 HFL greater than lO!am in length 99.99% <1 HFL N/A _>99% J-00102069
0.009 mg/L 0.009 mg/L ± 10% 94.4% 0.0005 mg/L 0.003 mg/L N/A J-00102058
0.016 mg/L 0.015 mg/L ± 10% 96.4% 0.001 mg/L 0.005 mg/L N/A J-00102065
0.08 mg/L 0.08 mg/L ± 10% 98.8% 0.001 mg/L 0.04 mg/L N/A J-00102059
104,750 cysts/L Minimum 50,000 cysts/L 99.99% 3 cyst/L N/A _>99.95% J-00102057
i[ ,! 0.140 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00102052
0.158 mg/L 0.15 mg/L ± 10% 98.3% 0.002 mg/L 0.010 mg/L N/A J-00102053
0.006 mg/L 0.006 mg/L ± 10% 91% 0.0003 mg/L 0.002 mg/L N/A 3-00102054
0.006 mg/L 0.006 mg/L ± 10% 88.3%% 0.0007 mg/L 0.002 mg/L N/A 3-00104087
0.002 mg/L 0.002 mq/L ± 10% 99% 0.00002 mq/L 0.0002 mq/L N/A 3-00102063
0.222 mg/L 0.225 mg/L ± 10% 99.8% 0.0005 mg/L 0.075 mg/L N/A 3-00102067
0.015 mg/L 0.015 mg/L ± 10% 93.5% 0.001 mg/L 0.003 mg/L N/A J-00102061
0.218 mg/L 0.210 mg/L±lO% 99.9% 0.0001 mg/L 0.07 mg/L N/A J-00102064
0.278 mg/L 0.300 mg/L ± 10% 97.7% 0.0015 mg/L N/A _>95% J-00102070
*Basedon the use ofCryptosporidium parvum oocysts.
The following pharmaceutical reduction claims have not been certified by NSFInternational. Claims tested and verified
Challenge Concentration
N/A
N/A
N/A
N/A
N/A
by independent laboratory:
Substance
Reduction
Avg %
Reduction
99.5%
99.4%
98.8%
99.4%
99.5%
Mox Permissible
Average Product woter Product Woter , NSE
Concentration Concentration Test Report
5.0 nq/L N/A 3-00103221
5.0 nq/L N/A 3-00103221
9.9 nq/L N/A 3-00103726
5.5 nq/L N/A 3-00103727
2.0 ng/L N/A J-O0103221
Application Guidelines!Water Supply Parameters
Service Flow Water Pressure
Water Su_ Water Temperature
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Note: While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: RPWFE. For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.
_WARNING
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems certified
for cyst reduction may be used on disinfected water that may contain filterable
cysts. EPAEstablishment Number 070595-HEX-O01.
NOTICE
To reduce the risk of water leakage or flooding, and to ensure optimal filter
performance:
• Read and follow use instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
• Do not install if water pressure exceeds 120 psi (827 kPa). Ifyour water pressure
exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain howto checkyour water pressure.
• Do not install where water hammer conditions may occun If water hammer
conditions exist you must install a water hammer arresten Contact a plumbing
professional if you a re uncertain how to check for this condition.
• Do not install on hot water supply lines. The maximum operating water
temperature of this filter system is 100 ° F (38° C).
• Protect filter from freezing. Drain filter when temperatures drop
below 33°F(0.6°C).
• Change the disposable filter cartridge every six months or sooner if you observe
a noticeable reduction in water flow rate.
• Failure to replace the disposable filter cartridge at recommended intervals may
lead to reduced filter performance and cracks in the filter housing, causing water
leakage or flooding.
(_ _sted and certified by NSFInternational
against NSF/ANSIStandard 42and Standard 53
in model GERPWF and GERPWFEfor the
reduction of the claims specified on the
REd,CEmeNT performance data sheet