10 Adjustable
wrenches (2)
8 Pipe wrench
Slip-joint pliers
Flat-blade screwdriver
Level
18
Installation Instructions
TOOLS YOU WILL NEED
CONNECTING A GAS DRYER (skip for electric dryers)
FOR YOUR SAFETY:
WARNING
Before beginning the installation, turn off
the circuit breaker(s) or remove the dryer’s circuit
fuse(s) at the electrical box. Be sure the dryer cord
is unplugged from the wall.
Turn the dryer’s gas shut-off valve in the supply
line to the OFF position.
Disconnect and discard old flexible gas connector
and ducting material.
Shut-off
Valve
MATERIALS YOU WILL NEED
4 dia. metal elbow
Pipe compound
Flexible gas line
connector
Duct clamps (2) or
Spring clamps (2)
Safety glasses
4 dia. metal duct
(recommended)
4 dia., UL-listed flexible
metal duct (if needed)
Gloves
Soap solution for
leak detection
Exhaust hood
Duct tape