3.8 TRANSPORTATION AND STORAGE
Transport or store the generator only if it has cooled completely.
Make sure the fuel valve and the vent on the fuel cap are both in
the OFF (“O”) position.
It is important to prevent gum deposits from forming in essential
fuel system parts such as the carburetor, fuel hose or tank during
long-term storage. Also, experience indicates that alcohol-blended
fuels (called gasohol, ethanol or methanol) can attract moisture,
which leads to separation and formation of acids; these acids can
damage the fuel system of an engine while in storage.
To avoid engine problems, the use of a commercial fuel stabilizer
prior to storage is recommended. Follow the manufacturer’s
instructions when adding the fuel stabilizer.
If the generator is going to be stored for more than six (6) months,
the generator should be prepared as follows:
1. Remove all gasoline from the fuel tank.
2. Start and run engine until engine stops from lack of fuel or
open the valve on carburetor bowl (Figure 13), and allow
gasoline to drain down tube into a receptacle. Discard
appropriately. Be sure to close the valve once the gasoline has
drained.
3. After the engine cools down, drain oil from crankcase. Refill
with recommended grade.
4. Remove spark plug and pour about 1/2 ounce (15 ml) of
engine oil into the cylinder. Cover spark plug hole with rag. Pull
the starting rope several times to coat the cylinder wall with
engine oil.
5. Install and tighten the spark plug.
6. Clean the generator outer surfaces. Check that cooling air
slots and openings on generator are open and unobstructed.
7. Store the unit in a clean, dry place.
Do not store gasoline from one season to another.
If possible, store the unit indoors and cover it to give protection
from dust and dirt.
Figure 13 - Carburetor Drain Valve
CARBUREATOR DRAIN
VALVE LOCATED BEHIND
AIR INTAKE
TURN VALVE COUNTER-
CLOCKWISE TO DRAIN FUEL,
CLOCKWISE TO CLOSE
Maintenance

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems IX 800 and is the answer not in the manual?

Generac Power Systems IX 800 Specifications

General IconGeneral
BrandGenerac Power Systems
ModelIX 800
CategoryPortable Generator
LanguageEnglish

Related product manuals