TROUBLESHOOTING
WARNING!
Symptom
Problem
NORMAL
FUNCTION
In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the
Power Supply Plug, and consult authorized service personnel.
Merely turning off the units power switch will not completely disconnect the unit from the power
source. Always be sure to disconnect the Power Supply Plug or turn off your circuit breaker to
ensure that power is completely off.
Before requesting service, perform the following checks:
Noise is heard:
Doesnt operate
immediately:
During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioners piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).
During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.
Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.
If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.
Whenever the Power Supply Plug is disconnected and then re-
connected to a power outlet, the protection circuit will operate for
about 3 minutes, preventing unit operation during that period.
Airflow is weak or stops: The fan may operate at very low speed during Dry operation or
when the unit is monitoring the rooms temperature.
During SUPER QUIET operation, the fan will operate at very low
speed.
In the monitor AUTO operation, the fan will operate at very low
speed.
During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of room
air by the air emitted from the air conditioner, resulting in con-
densation and misting.
Smells:
See Page
5
5
5
Mist or steam are
emitted:
9312355020-01_en.pm6 2004.2.5, 9:13 AM12