ON
1 2
3
4
5 6
7
8 9
10
COLPO D’ARIETE DISABILITATO / HAMMER STROKE DISABLEDCOLPO D’ARIETE ABILITATO / HAMMER STROKE ENABLED
FOTOCELLULA IN APERTURA ABILITATA
PHOTOCELL ACTIVE DURING OPENING ENABLED
MORSETTI 7-8 COME LAMPEGGIANTE A LUCE FISSA
TERMINAL INPUTS N°7-8 AS FIXED FLASHING LIGHT
MANTENIMENTO BLOCCO OLEODINAMICO ABILITATO
HYDRAULIC BLOCK MAINTENANCE ENABLED
LOGICA DI FUNZIONAMENTO CONDOMINIALE / WORKING LOGIC - AUTOMATIC
IMPOSTAZIONE DI DEFAULT DIP1 / DIP1 DEFAULT SETTINGS
4
15
FOTOCELLULA IN APERTURA DISABILITATA
PHOTOCELL ACTIVE DURING OPENING DISABLED
LOGICA DI FUNZIONAMENTO PASSO PASSO CON STOP
WORKING LOGIC - STEP BY STEP WITH STOP
FCA M1 ABILITATO / FCA M1 ENABLEDFCA M1 DISABILITATO / FCA M1 DISABLED
FCC M1 ABILITATO / FCC M1 ENABLEDFCC M1 DISABILITATO / FCC M1 DISABLED
FCC M2 ABILITATO / FCC M2 ENABLEDFCC M2 DISABILITATO / FCC M2 DISABLED
FCA M2 ABILITATO / FCA M2 ENABLEDFCA M2 DISABILITATO / FCA M2 DISABLED
INGRESSO PHOTO DISABILITATO / PHOTO INPUT DISABLED INGRESSO PHOTO ABILITATO / PHOTO INPUT ENABLED
MORSETTI 7-8 COME LUCE DI CORTESIA
TERMINAL INPUTS N°7-8 AS COURTESY LIGHT
MANTENIMENTO BLOCCO OLEODINAMICO DISABILITATO
HYDRAULIC BLOCK MAINTENANCE DISABLED
OFF
IMPOSTAZIONE DI DEFAULT DIP2 / DIP2 DEFAULT SETTINGS
16
ON
OFF
MORSETTI 23 COME COSTA 8K2 / TERMINAL INPUT N°23 AS 8K2 SAFETY DEVICE
MORSETTI 23 COME STOP N.C. / TERMINAL INPUT N°23 AS N.C. STOP
MORSETTO M4 COME SPIA / TERMINAL BLOCK M4 AS WARNING LIGHT
MORSETTO M4 COME LAMPEGGIANTE / TERMINAL BLOCK M4 AS FLASHING LIGHT
4
31
COLLEGAMENTO STOP N.C. / N.C. STOP CONNECTION
13
ON
1
OFF
DIP2_1 = OFF
M3
STOP /SAFETY
COM
SW15 =
4
31
COLLEGAMENTO STOP 8K2 / 8K2 STOP CONNECTION
14
ON
1
OFF
DIP2_1 = OFF
M3
STOP /SAFETY
COM
SW15 =
8K2
INUTILIZZATO / UNUSED
RECUPERO TEMPI NORMALE / NORMAL POSITIONAL TIME RECOVERY
INUTILIZZATO / UNUSED
RECUPERO TEMPI ESTESO / EXTENDED POSITIONAL TIME RECOVERY
F4
6
IT-UK
31
TRIMMER “P.S. TIME”
19
LEAVES PHASE SHIFT TIME DISABLED
SFASAMENTO ANTE DISABILITATO
TEMPO SFASAMENTO ANTA 2 IN APERTURA: FISSO 2 SECONDI
LEAF 2 CLOSING PHASE SHIFT TIME: 2 SECONDS NOT ADJUSTABLE
31
TRIMMER “PAUSE”
20
PAUSE 3 SECONDS
PAUSA 3 SECONDI
PAUSE 103 SECONDS
TEMPO PAUSA 103 SECONDI
LEAF 1 SHIFT TIME: CLOSING PHASE 20 SECONDS
SFASAMENTO ANTA 1 IN CHIUSURA: 20 SECONDI
31
TRIMMER “RUN TIME”
18
RUN TIME 136 SECONDS
TEMPO DI LAVORO 136 SECONDI
RUN TIME 3 SECONDS
TEMPO DI LAVORO 3 SECONDI
AUTOMATIC CLOSING DISABLED
CHIUSURA AUTOMATICA DISABILITATA
31
TRIMMER “FORCE”
MOVEMENT SPEED : - THRUST FORCE: 100% 25%
VELOCITA ANTA : 100% - FORZA DI SPINTA : 25%
MOVEMENT SPEED : - THRUST FORCE: 100% 100%
VELOCITA ANTA : 100% - FORZA DI SPINTA : 100%
17
RUN TIME LEARNING PROCEEDURE ENABLED
APPRENDIMENTO TEMPI ABILITATO