Main Panel
Sub Panel
120 VAC
120 VAC
240 VAC
ON
OFF
Battery Bank
Fuse or Circuit Breaker
IC Series Inverter/Charger
DC Panel
Earth Ground (RV, Boat Ground)
Equipment Grounding Bus Bar
Negative Bus Bar
Battery Charging Voltage
BULK
ABSORPTION
FINAL (FLOAT)
Battery Charging Current
Time
Battery Disconnect Switch
(not required if circuit breaker is used)
ON
OFF
D
C
A
B
BATTERY CHARGER SPECIFICATIONS
The IC Series Inverter/Charger is equipped with a PFC (Power Factor Corrected) and PI (Proportional Integral) multistage battery
charger. These 2 features maximize the real power from AC Shore Power. The multistage battery charger can use up to four
di󰀨erentchargingstagestohelpmonitorandkeepthebatterieshealthy.
Bulk Charging: This is the initial stage of charging. While bulk charging, the charger supplies the battery bank with controlled
constant current. The charger will remain in bulk charge until the absorption charge voltage is achieved.
Absorb Charging: This is the second charging state and begins after the absorb voltage has been reached. Absorb charging
provides the batteries with a constant voltage and reduces the DC charging current in order to maintain the absorb voltage setting.
Thefactorydefaultsettingforabsorbchargingis2hours.After2hoursofabsorbcharging,thechargerswitchestonalcharge.
Final (Float) Charging:Thethirdchargingstageoccursattheendofabsorbchargingtime.Whilenalcharging,thecharge
voltageisreducedtothenalchargevoltagesetpoint.Inthisstage,thebatteriesarekeptfullychargedandreadyifneeded
bytheInverter.Thenal(oat)chargingstagereducesbatterygassing,minimizeswateringrequirements,andensuresthe
batteries are maintained at optimum capacity.
Equalization Charging: TheEQchargingisusedtostirupstratiedelectrolyteandtoreverseanybatteryplatesulfationthat
may have occurred. The EQ charging mode can only be used with the GP-IC-Remote, sold separately by Go Power!.
BATTERY CHARGING SET POINTS
LED Status Gel Flooded AGM 1 AGM 2 Custom
Absorption
Voltage
14.1 VDC 14.6 VDC 14.3 VDC 14.5 VDC 12-16 VDC
Float
Voltage
13.6 VDC 13.4 VDC 13.1 VDC 13.5 VDC 12-16 VDC
Equalization
Voltage
15.5 VDC 15.5 VDC
OPERATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Go Power GP-IC-3000 and is the answer not in the manual?

Go Power GP-IC-3000 Specifications

General IconGeneral
BrandGo Power
ModelGP-IC-3000
CategoryBattery Charger
LanguageEnglish

Related product manuals