One apartment kit (KIT N5110/ ART 4 LITE 1P) and Golmar DC lock release.
Lock release
max. 12 Vdc/270mA.
One apartment kit (KIT N5110/ ART 4 LITE 1P), 1 additional ART 4 LITE monitor and Golmar DC
lock release.
4
NEXA ART 4 LITE G2+ VIDEO DOOR ENTRY SYSTEM KIT - VILLAS
APARTMENT 1
G2 Video Door Entry+
System Kit Nexa Art 4 Lite
QUICK GUIDE
Non-polarised 2 wire installation
Mains
100~240Vac
Web 2635Code 5012 TKIT632 ART 4 LITE E GRN REV.0121
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis .
Golmar reserves the right to make any modifications without prior notice.
golmar@golmar.es www.golmar.es
50122816
EN
Sistemas de comunicación S.A.
Distanc and Sections:es
MASTER MONITOR
ART 4 LITE/G2+
BUS BUS
Cable
RAP-GTWIN/HF 2x1mm
ON
1 2 3 4 5 6 7
8
FA-G2+
LN
BUS(PL)BUS (M)
2
( )
*
( )
FA-G2+ with output current: 1,5A.
2
( )
1
( )
ART 4 LITE
Access door panel
AP
NA2
+
AP-
C1
NA1
AP+
C2
AP+
GND
BUSBUS
Relé 2
Relé 1
_
12Vdc
NC2
CCTV
1 2 3 4 5 6 7 8 910
ON
B
150m
C
15m
A
80m
A
B
C
FA- 2G +
Set the microswitches on the monitor and
the door panel as shown in the installation
diagram for 1 apartment.
1
( )
CODE 128
*
( )
Configure end of line on last monitor.
Dip 8 to On.
( )4
( )4
1
( )
Apartment 1
Code 128
For AC lock releases or a second lock release, see the TKIT632 ART 4 LITE (cód. 50122635) manual.
2
Access door panel
APARTMENT 1
For AC lock releases or a second lock release, see the TKIT632 ART 4 LITE (cód. 50122635) manual.
https://doc.golmar.es/search/manual/50122635
4
( )
Lock release
max. 12 Vdc/270mA.
AP
( )4
NA2
+
AP-
C1
NA1
AP+
C2
AP+
GND
BUSBUS
Relé 2
Relé 1
_
12Vdc
NC2
CCTV
1 2 3 4 5 6 7 8 910
ON
Mains
100~240Vacc
FA-G2+
LN
BUS(PL)BUS (M)
2
( )
ART 4LITE
A
B
C
ART 4 LITE
FA- 2+G
To dene the monitor as master or slave, set the corresponding special code: "0550" master (factory default), 0551" slave 1
(seetheKIT632ART 4 LITE manual). Each apartment must haveonemaster monitor,and only one.
MASTER MONITOR
ART 4 LITE/G2+
BUS BUS
ON
1 2 3 4 5 6 7
8
C 128ODE
( )4
1
( )
SLAVE 1 MONITOR
ART 4 LITE/G2+
BUS BUS
ON
1 2 3 4 5 6 7
8
C 128ODE
1
( )
*
( )
Apartment 1
Code 128
A B
80m 150m
Cable
C
15m
RAP-GTWIN/HF 2x1mm
2
Distanc s and Sections:e
*
( )
FA-G2+ with output current: 1,5A.
2
( )
1
( )
Set the microswitches on the monitor and the
door panel as shown in the installation diagram
for 1 apartment withadditionalmonitor.
Configure end of line on last monitor.
Dip 8 to On.
1
( )
3
( )
3
( )
EN
TE NOLOGCH Y
4
( )

Related product manuals