09 Maintenance
NOTICE
When sunlight is insucient, the PV inverter may continuously start up and shut down
automatically due to insucient power generation from the PV panels, which would not lead
to inverter damage.
System
failure
PV Over
Voltage
1. Turn o DC switch rst, then take o the AC connector and DC
connector, check PV string voltage. Check if it exceeds the input
voltage in inverter specication.
2. If it does, please recongurate PV panel string.
3. If the problem still exists, please call the local service oce.
Over
Temperature
1. Turn o DC switch rst, then take o the AC connector and DC
connector
2. Reduce ambient temperature.
3. Move the inverter to a cool place.
4. If the problem still exists, contact local service oce for help.
Inverter
failure
Relay-Check
Failure
1. Disconnect the DC connector and AC.
2. Reconnect the DC connector.
3. If the problem still exists, please call the local service oce.
DCI Injection
High
EEPROM R/W
Failure
SPI Failure
DC BUS High
GFCI Failure
Others No display
1. Turn o DC switch, take o DC connector, measure the voltage
of PV array.
2. Plug in DC connector, and turn on DC switch.
3. If PV array voltage is lower than 150V , please check
conguration of invert module.
4. If voltage is higher than 150V and the problem still exists,
please contact local oce.