Page #13 background image
Max.DC Input Power(W)
Max.DC Input voltage(V)
Start-up
MPPT Range for Full Load (V)
Nominal DC Input Voltage (V)
Max. Input Current (A)
Max. Short Current (A)
No.of MPP Trackers
No.of Input Strings per Tracker
PV String Input Data
Technical Data
Nominal Output Power (W)
Max. Output Apparent Power (VA)
Nominal Output Voltage (V)
Nominal Output Frequency(Hz)
Max. Output Current (A)
Output Power Factor
Output THDi (@Nomina Output)
Europe efficiency
Anti-islanding Protection
Input Reverse Polarity Protection
Insulation Resistor Detection
Residual Current Monitoring Unit
Output Over Current Protection
Output Short Protection
5200 6500 7800 9600 10800 12000
1000 1000 1000 1000 1000 1000
200~800 200~800 200~800 200~850 200~850 200~850
620 620 620 620 620 620
11/11 11/11 11/11 11/11 11/11 11/11
180 180 180 180 180 180
195~800 240~800 285~800 380~850 430~850 480~850
13.8 13.8 13.8 13.8 13.8 13.8
2 2 2 2 2 2
1 1 1 1
1
1
4000 5000 6000 8000 9000 10000
4000
400,3L/N/PE
50/60
5000 6000 8000 9000 10000
400,3L/N/PE 400,3L/N/PE 400,3L/N/PE
400,3L/N/PE
400,3L/N/PE
50/60 50/60 50/60 50/60 50/60
8.5 8.5 10 12.1 13.6 15.2
~1(Adjustable from 0.8 leading to 0.8 lagging)
<2%
>97.5%
98.0% 98.3%
>98.0%
DC Backfeed Current
Over Voltage Category
0
II
AC Backfeed Current
Over Voltage Category
0
III
AFD
DC Overcurrent Protection(A)
AC Overcurrent Protection(A)
17
Current (inrush) a.c. A
Maximum output fault
current a.c. A (peak and duration)
17 17 17 17 17
16 16 16 25 25 25
30A 40us
15A 2 su15A 2 su15A 2 su15A 2 su15A 2 su15A 2 su
30A 40us 30A 40us 40A 40us 40A 40us 40A 40us
6 Technical Parameters and Block Diagram
6.1 Technical Parameters
GW4000-DT GW5000-DT GW6000-DT GW8000-DT GW9000-DT GW10KN-DT
Operating Altitude(m)
User Interface
Communication
Size Width*Height*Depth mm( )
Night self consumption(W)
4000
al
LCD&LED
VDE-AR-N 4105,VDE0126-1-1
EN50438(PL),EN50438(SW)
G83,IEC61727,AS4777.2
IEC62116,EN50438(IR)
ERDF-NOI-RES_13E
EN61000-6-1,EN61000-6-2,EN61000-6-3,EN61000-6-4
24
516*415*192
Technical Data
Moisture Location Category
4K4H
Environment category
OutdoorIndoor
External Environment Pollution Degree
Grade123
Output Over Voltage Protection
Operating Temperature Range(℃)
Weight(kg)
Protection degree
Topology
IP65
0~100%
-25~60
GW4000-DT GW5000-DT GW6000-DT GW8000-DT GW9000-DT GW10KN-DT
Zref :
SDT4~10KW:
RA = 0.24 ; XA = j 0.15 at 50 Hz; RN = 0.16 ; XN = j 0.10 at 50 Hz.
Note
Overvoltage category definition
Category I: applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a
low level.
Category II: applies to equipment not permanently connected to the installation. Examples are appliances, portable tools and
other plug-connected equipment;
Category III: applies to fixed equipment downstream of and including, the main distribution board. Examples are switchgear and
other equipment in an industrial installation;
Category IV: applies to equipment permanently connected at the origin of an installation (upstream of the main distribution board)
Example are electricity meters, primary overcurrent protection equipment and other equipment connected directly to
outdoor open lines.
Moisture location category definition
Noice emission of the inverter is up to civil standard, but not suitable for installtion inside or living quarters.