2
EN
Product:
1. Do not apply mechanical load to the terminals, otherwise the terminals can be damaged.
2. All labels and warning marks should be visible after the installation. Do not scrawl, damage,
or cover any label on the device.
3. Unauthorized dismantling or modication may damage the equipment, the damage is not
covered under the warranty.
4. Install the inverter away from high magnetic eld to avoid electromagnetic interference.If
there is any radio or wireless communication equipment below 30MHz near the inverter, you
have to:
• Install the inverter at least 30m away from the wireless equipment.
• Add a low pass EMI lter or a multi-winding ferrite core to the PV-DC input cable or AC
output cable of the inverter.
5. Warning labels on the inverter are as follows.
Check before Power-on
No. Check Item
1
The product is rmly installed at a clean place that is well-ventilated and easy-to-
operate.
2
The PE, DC input, AC output, and communication cables are connected correctly and
securely.
3 Cable ties are intact, routed properly and evenly.
4 Unused ports and terminals are sealed.
5
The voltage and frequency at the connection point meet the inverter grid connection
requirements.
HIGH VOLTAGE HAZARD
Disconnect all incoming
power and turn o the
product before working on it.
Delayed discharge. Wait 5
minutes after power o until
the components are completely
discharged.
Read through the user
manual before any
operations.
Potential risks exist. Wear
proper PPE before any
operations.
High-temperature hazard. Do
not touch the product under
operation to avoid being
burnt.
Grounding point.
CSA marking for the United
States of America and Canada
Do not dispose of the inverter
as household waste. Discard
the product in compliance with
local laws and regulations,
or send it back to the
manufacturer.
300612