Operation
10 3A2988C
Operation
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
Relieve A and B Fluid Pressure
1. Engage trigger lock.
2. Press Stop to turn sprayer OFF.
3. Close all air motor supply valves or any source of
fluid pressure.
4. If fluid heaters are used, shut them off using the
controls on the display module.
5. Shut off RAM air supply.
6. Disengage trigger lock.
7. Hold a metal part of the gun firmly to a grounded
metal pail with a splash guard in place. Trigger gun
to relieve pressure in material hoses.
8. Engage trigger lock.
9. Close the mix manifold inlet ball valves (C, D).
10. Flush mixed material hoses, mixer, and gun. See
Flush on page 11.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
ti19265a1
ti19265a1
ti19269a

Other manuals for Graco Simulation XM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Simulation XM and is the answer not in the manual?

Graco Simulation XM Specifications

General IconGeneral
BrandGraco
ModelSimulation XM
CategoryPaint Sprayer
LanguageEnglish

Related product manuals