8 Troubleshooting
If your air conditioner is not working well, please check the following table first before asking for
service:
Phenomenon Troubleshooting
The unit can’t start
Power supply is not connected
Circuit breaker tripping caused by leakage of electricity
Input voltage is too low
Operation button is off
Error of control loop
The unit stops after running for a
while.
There is obstacle in front of condenser
Error of control loop
Perform cooling when outdoor ambient temperature is higher than 43
Poor cooling effect
The filter is dirty or blocked
Too heavy heat load of room(e.g. too many people)
Door or windows is open
Air inlet and outlet of IDU are blocked
Set temperature is too high or refrigerant leaks
The performance of room temperature sensor gets worse
Poor heating effect
The filter is dirty or blocked
Door or window is open
Set temperature is too low
Refrigerant leaks
Outdoor ambient temperature is lower than -5
Error of control circuit
Indoor fan doesn’t start
up during heating
Position of tube temperature sensor is improper
Tube temperature sensor is not inserted well
Wiring of tube temperature sensor breaks off
Electrical leakage of capacitor
Note:
If air conditioner still fails to work normally after checking and handling as described above, please
stop using it immediately and contact local service center for assistance.