Technical Information
Service Manual
5. Electrical Part
5.1 Wiring Diagram
● Indoor Unit
● Instruction
Symbol Symbol Color Symbol Symbol Color Symbol Name
WH White GN Green CAP Jumper cap
YE Yellow BN Brown COMP Compressor
RD Red BU Blue Grounding wire
YEGN Yellow/Green BK Black / /
VT Violet OG Orange / /
Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.
STEPPING
CAP
BLOCK
TERMINAL
G
EVAPORATOR
JUMP
AP2: MAIN BOARD
YEGN
BK
BN
YEGN
N1
2
N(1)
XT1
BU
AC-L
COM-OUT
COM-MANUAL
CONNECTOR
AP3
WIRED
MOTOR
OUTDOOR UNIT
T-SENSOR DISP2DISP1
RT1
θ
AP1
ROOM
TUBE
TEMP.SENSOR
TEMP.SENSOR
DISPLAY BOARD
RECEIVER AND
θ
RT2
SWING-UD
M2
ELECTRIC BOX
G
CONTROLLER
WH(BU)
BK
RD(BN)
GN(YEGN)
3
63610000441
PGFPG
FAN
MOTOR
M1