122
Installation and Maintenance
Service Manual
11.2 Removal Procedure of Outdoor Unit
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
top cover
3. Remove panel and grille
2. Remove cable cross plate sub-assy and valve cover
1. Remove top cover
cable cross
plate sub-assy
valve cover
panel
grille
Remove the screws connecting top cover, left and
right side plate, as well as panel, to remove the top
cover.
Remove the screws fixing panel, to remove the panel.
Remove the screws connecting panel grille and panel,
loosen the clamp, to remove the panel grille.
Remove the screws connecting
cable cross plate
sub-assy
and right side plate, to remove the cable
cross plate sub-assy
. Remove the screw fixing
valve cover, to remove the cover.
Steps Procedure