Service Manual
6.Remove motor and axial ow blade
1
2
Remove screws of step motor and then
remove the motor.
Remove the screw of the motor press
plate and then remove the press plate.
Remove the screws at the joint of the
cross flow blade and the motor. Take
down the motor.
Remove the cross ow blade.
Procedure
Steps
Motor Press Plate
Step Motor
Motor
Cross Flow Blade
66