11.2 Removal Procedure of Outdoor Unit
Procedure Steps
1.Remove big handle
2. Remove top cover
top cover
big handle
Before disassamble
Remove 1 connection screw fixing big
handleand then removethe big handle.
Remove 3 connection screws among
top cover plate, front panel and right
sideplate. Then remove top cover
plate.
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.