8
Technical Information
Service Manual
2.2 Operation Characteristic Curve
0 10203040506070 90
80
0 102030405060708090100 120110
11
10
9
8
7
6
5
4
3
2
1
0
Compressor speed (rps)
)A(tnerruC
11
10
9
8
7
6
5
4
3
2
1
0
Compressor speed (rps)
)A(tnerruC
Conditions
Indoor: DB27°C/WB19°C
Indoor air flow: High
Pipe length: 5m
Conditions
Indoor: DB20°C/WB15°C
Indoor air flow: High
Pipe length: 5m
Cooling Heating
0
1
2
3
4
5
6
7
8
9
10
0 20 40 60 80 100 120
Condition
Indoor:DB 27°C WB19°C
Indoor air flow: Turbo
Pipe length:5m
Voltage:230V
Compressor Speed(rps)
0
1
2
3
4
5
6
7
8
0 20 40 60 80 100 120
Condition
Indoor:DB 20°C
Indoor air flow:Turbo
Pipe length:5m
Voltage:230V
Compressor Speed(rps)
Current(A)
Current(A)
09K/12K
18K
Cooling Heating