EasyManuals Logo

Gree GWH18AGC-K3NNA1A/I User Manual

Gree GWH18AGC-K3NNA1A/I
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
43
Installation and Maintenance
Service Manual
9.2 Procedure of Troubleshooting
1. Malfunction of Temperature Sensor F1, F2
Main detection points:
● Is the wiring terminal between the temperature sensor and the controller loosened or poorly contacted?
● Is there short circuit due to trip-over of the parts?
● Is the temperature sensor broken?
● Is mainboard broken?
Malfunction diagnosis process:
Is the wiring terminal between the
temperature sensor and the controller
loosened or poorly contacted?
Start
Insert the temperature
sensor tightly
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Is malfunction
eliminated
Is malfunction
eliminated
Is malfunction
eliminated
Replace it with a
temperature sensor with
the same model
Make the parts upright
Is there short circuit due to trip-
over of the parts
Is the temperature sensor normal
according to the resistance table?
Replace the mainboard with
the same model.
End

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH18AGC-K3NNA1A/I and is the answer not in the manual?

Gree GWH18AGC-K3NNA1A/I Specifications

General IconGeneral
BrandGree
ModelGWH18AGC-K3NNA1A/I
CategoryAir Conditioner
LanguageEnglish

Related product manuals