OM-CC-E
24
NOTE:
It is strongly recommended that the unit be
run through a Clean Cycle after manual
cleaning. Repeat as necessary.
WARNING
DO NOT PUT HANDS OR OTHER OBJECTS
INTO THE COOKING CHAMBER WHILE THE FAN
IS TURNING.
1. If the unit has been operating in the Oven or
Combo Mode, allow it to cool or use the
Fast Cool procedure described in the
Operations Section (Page 18).
2.
When the unit has cooled enough to be
cleaned, switch it off by pressing the ON
touch pad.
3. Remove the right side panel from the cooking
chamber.
4.
Using Easy-Off
®
Oven Cleaner or a
comparable product, thoroughly coat all
inside surfaces of the chamber, including the
right side panel. Follow the manufacturer’s
instructions on the cleaning agent label.
5. Install the right side panel.
6.
Rinse and wipe down the cooking chamber
with a cloth and plenty of clean water. Rinse
the cloth often.
Maintenance
The Groen Convection Combo™ is designed for
minimum maintenance. Certain parts may need
replacement after prolonged use. If there is a need
for service, only Groen personnel or authorized
Groen representatives should perform the work.
Always supply water with a low mineral count that
meets the standards outlined in the Water
Conditioning section of this manual.
If steam or condensate is seen leaking from around
the door, take the following steps:
1.
Check the door gasket. Replace if it is cracked
or split. Inspect the cooking chamber drain to be
sure it is not blocked.
2.
Adjust the latch pin as follows:
a. Loosen the lock nut at the base of the latch
pin, and turn the latch pin ¼ turn clockwise.
Re-tighten the lock nut.
b. After adjustment, run the unit to test for
further steam leaks.
c. If there is still leakage, repeat the
adjustment.
d. Continue adjusting the pin clockwise until the
door fits tightly enough to prevent leaks.
Troubleshooting
A.
Resetting the Solid State Controls
(If problems persist call an authorized Groen
Service Agency)
If the controls stop responding to normal
operations, or the unit is behaving oddly, reset
the controls using the following procedure:
1. Switch off the power by pressing the ON
touch pad.
2. While pressing the COMBO touch pad,
switch the power back on. If no errors are
present the unit will beep and show four
zeroes in the display. If there are errors, the
unit will not beep, but will display Service
Codes, in the timer and cook temperature
displays. Note the Service Codes. Press
CLEAR to exit Service Mode and refer to the
following explanation of service messages.
B.
Service Messages
There are two types of service message:
1. Non-critical error: signaled by three quick
beeps. The SERVICE light comes on for 15
seconds and then goes out.
2.
Critical error: signaled by a continuous five
second beep. The SERVICE comes on and
stays on.
If there is a non-critical error you may continue to
operate the unit. When possible, inspect the Service
Code. Turn off the unit by pressing the ON touch
pad. While pressing the COMBO touch pad, switch
the power back on. Note the numbers and refer to
the Troubleshooting Guide which follows. Press
CLEAR to exit the Service Mode. If there is a critical
error, the unit will not operate in its current mode, but
may operate in another. Inspect the Service Code
as described above, and call your authorized Groen
Service Agency.