11.3 Inverter warning
Warning code
Meanings
Suggestion
Warning202
DC SPD function abnormal
1.After shutdown,Check the DC SPD.
2.If error message still exists,contact
manufacturer.
Warning 203
PV1,PV2 or PV3Circuit short
1.Check the PV panel polarity.
2.Restart the inverter.
3.If the warning still exist, please contact
Growatt customer service to replace the
POWER board.
Warning204
Drycontact function abnormal
1.After shutdown,Check the dry
Dryconnect wiring.
2.If the error message still exists, contact
manufacturer.
Warning 205
PV1,PV2 or PV3 boost broken
Restart the inverter. If the warning still
exist, please contact Growatt customer
service to replace the power board.
Warning207
USB over-current
1: Unplug the U disk or monitor.
2: Re-access U-stick or monitor after
shutdown.
3.If the error message still exists, contact
manufacturer.
Warning 401
Inverter communicates with
Meter abnormal
1: Check if the meter is on
2: Check the inverter and the meter
connection is normal
Warning404
EEPROM abnormal
Restart the inverter. If the warning still
exist, please contact Growatt customer
service to replace the M3 board.
Warning405
Firmware version is not
consistent
Uptate the right version firmware
11.4 Inverter fault
Error code
Meanings
Suggestion
Error: 402
Output High DCI
Restart inverter, if problem still exist,
Contact Growatt.