Solar energy provides power to the loads as
first priority. If solar energy is not sufficient to
power all connected loads, battery energy will
supply power the loads at the same time.
Utility (during utility’s powering load time)
provides power to the load only when anyone
condition happens:
- Solar energy is not available
- Battery voltage drops to either low-level
warning voltage or the setting point in
“Battery Low Volt”
Utility (during utility’s powering load time)
will provide power to the load as first priority.
Solar and battery energy will provide power to
the load only when utility power is not
available.
Solar energy provides power to the load as
first priority. If solar energy is not sufficient to
power all connected loads, battery energy will
supply power to the loads at the same time.
Utility (during utility’s powering load time)
provides power to the load only when battery
voltage drops to either low level warning
voltage or the setting point in “Battery Low
Volt”.
The time when utility start to power the load.
Setting range from 0H to 23H.
The time when utility end to power the load.
Setting range from 0H to 23H.
Solar energy will charge battery as first
priority.
Utility (during utility’s charging time) will
charge battery only when solar energy is not
available.
LCD description:
After pressing and holding ENTER button for 3 seconds, the unit will enter setting
mode. Press “UP” or “DOWN” button to select setting programs. And then, press
“ENTER” button to confirm the selection or ESC button to exit.
Solar energy and utility (during utility’s
charging time) charge the battery at the same
time.
Solar energy charges the battery only.
The time when utility start to charge the
battery. Setting range from 0H to 23H.
The time when utility end to charge the
battery. Setting range from 0H to 23H.
Two solar input parallel.
Two solar input independent.
AC output voltage 208VAC.
AC output voltage 230VAC.
AC output voltage 240VAC.
AC output frequency 50Hz.
AC output frequency 60Hz.
Enable auto restart when overload occurs.
Disable auto restart when overload occurs.
If overload occurs in battery discharge mode,
utility provides power to the load.