Enable auto restart when temperature occurs.
Disable auto restart when temperature
occurs.
If battery type is selected as lead acid battery,
this program can be set up. SPF5000: Setting
range is from 10A to 130A.
SPF3000: Setting range is from 10A to 100A.
If battery type is selected as “self-defined
Lead_Acid”, this program can be set up.
Setting range is from 50.0V to 57.4V.
If battery type is selected as “self-defined
Lead_Acid”, this program can be set up.
Setting range is from 50~56V.
Setting voltage point back to battery mode
when selecting“BAT first” or “PV first”.
Setting range is from 44.4~51.4V.
Setup communication address
Table 6.7
Error description:
Over Load with Lithium battery
M3 failed to communicate with DSP
The sample from M3 and DSP of the battery voltage is inconsistent
Reverse polarity protection diode failed
Communication failed between DSP and M3
AC output voltage is too high