5-minute delay function
If starting up the unit after being powered off, the compressor will run about 5 minutes later against being damaged.
Cooling/heating operation
Indoor units can be controlled individually, but cannot run in cool and heat mode at the same time. If the cool mode and
the heat mode are existing simultaneously, the unit set latter will be standby, and the unit set earlier will run normally. If
the A/C manager sets the unit at cooling or heating mode xedly, the unit can not run at the other modes.
Heating mode characteristic
In operation if outdoor temp. arises, indoor fan motor will turn to low speed or stop.
The unit operation condition
To use the unit properly, please operate the unit under the allowed condition range. If operating beyond the range, the
protection device will act.
The relative humidity should be lower than 80%. If the unit runs at the humidity over 80% for a long period, the dew on
the unit will drop down and the vapour will be blowed from air outlet.
Protection device (such as high pressure switch)
High pressure switch is the device which can stop the unit automatically when the unit runs abnormally.
When the high pressure switch acts, the cooling/heating mode will stop but the running LED on wired controller will be
light still. The wired controller will display failure code.
When the following cases occur, the protection device will act:
In cooling mode, air outlet and air inlet of outdoor are clogged.
In heating mode, indoor lter is sticked with duct; indoor air outlet is clogged.
When protection device acts, please cut off the power source and re-start up after eliminating the trouble.
Defrosting in heating mode
In heating mode, outdoor defrosting will affect the heating efciency. The unit will defrost for about 2~10 minutes
automatically, at this time, the condensate will ow from outdoor, also in defrosting, the vapour will appear at outdoor,
which is normal. Indoor motor will run at low speed or stop, and outdoor motor will stop.
Trial operation and the performance
When power failure
When power is failure in running, all the operations will stop.
After being electried again, if with re-satrt up function, the unit can resume to the state before power off automatically;
if without re-satrt up function, the unit needs to be switched on again.
When abnormal occurs in running because of the thunder, the lightning, the interference of car or radio, etc, please cut
off the power source, after eliminating the failure, press "ON/OFF" button to start up the unit.
Heating capacity
The heating mode adopts the heat pump type that absorbs outdoor heat energy and releases into indoor. So if outdoor
temperature goes down, the heating capacity will decrease.
System marks
On the condition that multi Outdoor systems are installed, in order to conrm the relationship between outdoor and
indoor, please make marks on outdoor electric control box cover to indicate the connected indoor unit. As the below
gure:
Indoor model:
Room No.
e.g. Indoor A, system 1, Floor 2 2F-1A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier AU282FHERA(H) and is the answer not in the manual?

Haier AU282FHERA(H) Specifications

General IconGeneral
BrandHaier
ModelAU282FHERA(H)
CategoryAir Conditioner
LanguageEnglish

Related product manuals