Topic Title
INTRODUCTION
A-3
ENGLISH
Specications
Outdoor Units
Compressor Type:
DC Inverter Driven Rotary
Voltage/Cycle/Phase:
208-230/60/1
Operating Range (
O
F):
Outdoor Units
2U18MS2VHB 3U24MS2VHB 4U36MS2VHB
Cooling Non-
ducted
Rated Capacity Btu/hr 17,400 22,600 34,000
Capacity Range Btu/hr 4,400-19,400 5,000-24,500 5,000-36,000
Rated Power Input W 1,650 2,250 3,770
SEER/EER 16.0/10.5 18.0/10.0 18.0/9.0
Cooling Ducted
Rated Capacity Btu/hr 15,000 21,000 31,000
Capacity Range Btu/hr 4,400-19,400 5,000-23,000 5,000-34,000
Rated Power Input W 1,760 2,416 3,590
SEER/EER 16.0/8.5 16.0/8.5 16.0/8.5
Heating Non-
ducted
Rated Heating Capacity 47°F Btu/hr 19,200 23,000 34,600
Heating Capacity Range Btu/hr 6,100-22,100 6,100-25,500 6,100-36,500
Rated Power Input W 1,570 1,700 2,650
HSPF 9.0 10.0 10.0
Rated Heating Capacity 17°F Btu/hr 13,000 15,000 22,000
Heating Ducted
Rated Heating Capacity 47°F Btu/hr 18,000 22,000 33,000
Heating Capacity Range Btu/hr 6,100-22,100 6,100-25,000 6,100-35,000
Rated Power Input W 1,700 2,100 3,000
HSPF 8.5 8.5 9.0
Rated Heating Capacity 17°F Btu/hr 10,000 14,000 21,000
Outdoor Unit
Maximum Fuse Size A 25 25 30
Minimum Circuit Amp A 15 18 23
Outdoor Fan Speed RPM 300 ~ 900 300 ~ 900 300 ~ 900
OutdoorNoiseLeveldB 53 54 56
Dimension: Height in (mm) 27 1/16 (688) 28 3/4 (730) 33 1/16 (840)
Dimension: Width in (mm) 31 7/8 (810) 33 7/8 (860) 37 5/16 (948)
Dimension: Depth in (mm) 11 5/16 (288) 12 1/8 (308) 13 3/8 (340)
Weight(Ship/Net)-lbs(kg) 102.5/95.9 (46.5/43.5) 123.4/116.8 (56/53) 191.8/167.5 (87/76)
Connectable Indoor unit quantity 2 2 or 3 2, 3 or 4
Piping
Connections Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Suction O.D. in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2
Factory Charge Oz 49.5 67.0 113.0
Maximum Line Length Ft / m 100/30 200/60 230/70
Maximum Height Ft / m 50/15 50/15 50/15
Maximum Line Length (each individual indoor
unit) Ft / m
65/25 82/25 82/25
2 Zones 3 Zones 4 Zones
-22 1151450-4
-15
Cooling
Heating
75

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier AW07EH2VHA and is the answer not in the manual?

Haier AW07EH2VHA Specifications

General IconGeneral
BrandHaier
ModelAW07EH2VHA
CategoryHeat Pump
LanguageEnglish

Related product manuals