CONNECT SERIES SERVICE MANUAL
52
ENGLISH
Maintenance
Compressor/Gas Liquid Separator Removal
Note: Make sure all refrigerant is recovered and power is isolated before removing compressor and gas liquid separator.
Step Picture Work instruction
5. Install the new compressor/
gas liquid separator onto the
chassis.
After replacing the compressor/gas
liquid separator, tighten up the base
screw nuts.
6. Connect the brazing
interfaces of compressor/gas
liquid separator to the pipeline.
Braze the connection pipes of
compressor to connect them to the
compressor.
Note: When replacing the
compressor, avoid touching the
nearby pipeline and components.
7. Connect the compressor
wires.
Connect the compressor wires to
the wire terminals on the top of
compressor.
Note: When connecting the wires,
be sure to match the colors with the
corresponding wire terminals.