EasyManuals Logo

Hayward H350FDN User Manual

Hayward H350FDN
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
Isolate the blower vacuum switch. Measure
continuity between switch terminals. IF continuity
exist, replace switch (pg. 20). IF OK, go to 13B.
Verify blower operation
Test blower vacuum switch
Step 13A
57
Step 13B
“AC” Code stands for “Air Switch Closed”. The blower vacuum switch closed, when it
was expected to be open.
With the heater off (in “Stand By”), IF the blower
continues to run/operate, replace the ICB. IF not,
replace the blower vacuum switch (pg. 20).
13. Service LED ON: “AC” Code

Other manuals for Hayward H350FDN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward H350FDN and is the answer not in the manual?

Hayward H350FDN Specifications

General IconGeneral
BrandHayward
ModelH350FDN
CategoryHeater
LanguageEnglish

Related product manuals