Automation and Chlorination
Operation Manual
for models
PL-PS-4 PL-PS-8-V
PL-PS-8 PL-PS-16-V
PL-PS-16
Quarterly Monthly Weekly
Free Chlorine 1.0 - 3.0 ppm
pH 7.2 - 7.8
Raise desired output % to
increase, lower desired output %
to decrease -OR- increase or
decrease pump filtration time.
Too low - add soda ash.
Too high - add muriatic acid
Alkalinity 80 - 120 ppm
Salt 2700 - 3400 ppm Add salt as required to increase.
Add baking soda to increase.
Stabilizer 60 - 80 ppm Add cyanuric acid to increase.
Calcium 200 - 400 ppm Add calcium to increase.
Electrolytic Cell inspect & clean Refer to section in manual.
TEST IDEAL RANGE ADJUSTMENT REQUIRED
Drain and add water to decrease.
Add acid as required to decrease.