USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
Installation
If replacing an existing light, remove power to the light at the panel before starting this installation. Installation must be performed in accordance with Local
and NEC codes.
Cord Length and Minimum Required Voltage
When installing Universal ColorLogic/CrystaLogic low voltage lights, the length of the cord has an effect on performance. To prevent performance problems,
verify the transformer is providing the minimum required voltage according to the table below. To check this voltage, measure the voltage at the transformer
while the light is “on” and operating in “white” mode. In some cases, a voltage greater than 12 volts is required due to a long cord run. Some transformers
provide higher voltage taps for this purpose; check your transformer manufacturer’s installation instructions for details. When using Hayward or other trans-
formers that offer a 14v option, we suggest that you always use the 14 volt tap.
Install Niche (new installations)
NOTE: For installation of Hayward niches, see installation instructions provided with the unit. The light fixture must be installed in or on a wall of
the pool or spa with the top of the lens not less than 4 inches (10 cm) below the normal water level of the pool except when the fixture is installed in an area
of the swimming pool that is not used for swimming. Select a location for the light fixture(s) that will give optimum light dispersion for the pool or spa design.
Be sure to consider the direction of emitted light and take care not to point lights directly at the house or outdoor living spaces.
Product
Total Cord Length
from Transformer
to Light
12v Universal
ColorLogic
Pool Light
12v Universal
ColorLogic
Spa Light
Minimum Required
Voltage at
Transformer
30 ft
50 ft
100 ft
30 ft
50 ft
100 ft
12 - 14 volts
12 - 14 volts
13 - 14 volts
13 - 14 volts
14 volts
14 volts

Other manuals for Hayward Universal ColorLogic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward Universal ColorLogic and is the answer not in the manual?

Hayward Universal ColorLogic Specifications

General IconGeneral
BrandHayward
ModelUniversal ColorLogic
CategoryLight Fixture
LanguageEnglish

Related product manuals