Electrical connections
The sauna heater must be connected to the mains by a qualified electrician and in compliance with current
regulations. The steam generator is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66)
or a corresponding type cables
Output
kW
Generator con-
nection cable
H07RN-F / 60245
IEC 66
mm
2
400V-415V 3N~
Fuse
A
Generator con-
nection cable
H07RN-F / 60245
IEC 66
mm
2
230V 3~
Fuse
A
Generator connec-
tion cable
H07RN-F /
60245 IEC 66
mm
2
230V-240V 1N~/2~
Fuse
A
Room
size
*)
m
3
3.4 5 x 1.5 3 x 10 4 x 1.5 3 x 10 3 x 2.5 16 1,5 – 2,5
4.7 5 x 1.5 3 x 10 4 x 2.5 3 x 16 3 x 6.0 25 2,5 – 5
6.0 5 x 1.5 3 x 10 4 x 2.5 3 x 16 3 x 6.0 25 5 – 7
7.7 5 x 2.5 3 x 16 4 x 6 3 x 25 3 x 10 35 7 – 10
9.5 5 x 2.5 3 x 16 4 x 6 3 x 25
------ ------
10 – 12
12.0 5 x 6 3 x 25 4 x 10 3 x 35
------ ------
12 – 15
14.0 5 x 6 3 x 25 4 x 10 3 x 50
------ ------
15 - 18
Main switch
There is a main switch at the bottom of one end of the steam generator, which is used only when the steam room is
not to be used for a long period of time.
The steam generator's automatic flushing and rinsing function will stop, if the power is switched off.
(Optional, Automatic drain valve)
Steam generator's heating elements
Teho
Power
Leistung
Vastus / Element / Heizstäbe 230V
1 2 3
3.0
3.4
4.7
6
7.7
1000W/SEPD 131
1150W/SEPD 97
1567W/SEPD 98
2000W/SEPD 99
2567W/SEPD 100
1000W/SEPD 130
1150W/SEPD 111
1567W/SEPD 112
2000W/SEPD 113
2567W/SEPD 114
1000W/SEPD 131
1150W/SEPD 97
1567W/SEPD 98
2000W/SEPD 99
2567W/SEPD 100
9.5
12
14
5250W/SEPD 116
4250W/SEPD 119
5250W/SEPD 116
3500W/SEPD 115
3500W/SEPD 115
3500W/SEPD 115
5250W/SEPD 116
4250W/SEPD 119
5250W/SEPD 116
User and installation manual HNS-M2