22
5. Edit the zone name.
6. Check linked areas.
Note
Only enabled areas will be listed.
The newly added peripheral is linked to area 1 by default.
7. Select a zone type.
Instant Zone
This Zone type will immediately trigger an alarm event when armed.
Delay Zone
-Exit Delay: Exit Delay provides you time to leave through the zone without alarm.
Arm with faults is enabled: You should confirm faults first, and then the zone is in arming
process. If the delay zone is triggered within the exit delay time but it restores before the
time ends, the alarm will not be triggered and the zone will be armed.
Arm with faults is disabled: Immediately armed. If the delay zone is triggered within the exit
delay time but it restores before the time ends, the alarm will not be triggered.
-Entry Delay: Entry Delay provides you time to enter the zone to disarm the system without
alarm.
After triggering, if the zone is not disarmed or silenced before the entry delay time ends, the
zone will alarm.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION AX HYBRID PRO and is the answer not in the manual?

HIKVISION AX HYBRID PRO Specifications

General IconGeneral
BrandHIKVISION
ModelAX HYBRID PRO
CategorySecurity System
LanguageEnglish

Related product manuals