Network Video Recorder Quick Start Guide
13
Figure 2-4 Alarm Input Wiring
2.3.2 Alarm Output Wiring
To connect to an alarm output (AC or DC load), use the following diagram:
Figure 2-5 Alarm Output Wiring
For DC load, the jumpers can be used within the limit of 12V/1A safely.
To connect an AC load, jumpers should be left open (you must remove the jumper on the
motherboard in the NVR). Use an external relay for safety (as shown in the figure above).
There are 4 jumpers (JP6, JP9, JP10, and JP11) on the motherboard, each corresponding with one
alarm output. By default, jumpers are connected. To connect an AC load, jumpers should be
removed.
Example:
If you connect an AC load to the alarm output 3 of the NVR, then you must remove the JP 3
jumper.
2.3.3 Use Alarm Connectors
To connect alarm devices to the NVR:
Step 1 Disconnect pluggable block from the ALARM IN /ALARM OUT terminal block.
Step 2 Unfasten stop screws from the pluggable block, insert signal cables into slots and fasten stop
screws. Ensure signal cables are tight.
Step 3 Connect pluggable block back into terminal block.

Other manuals for HIKVISION DS-9600NI-M8 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-9600NI-M8 Series and is the answer not in the manual?

HIKVISION DS-9600NI-M8 Series Specifications

General IconGeneral
BrandHIKVISION
ModelDS-9600NI-M8 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals