Because 10.1 W ≤ 16 W, we can support powering this device
through KAD706 channel 6 or KAD704 channel 4.
2-Wire
Model
DS-KD8003-
IME2
DS-KD-M DS-KD-KK /
Quanty 1 1 12 /
Power 4 W 0.8 W 9.6 W
Total: 14.4
W
Because 14.4 W ≤ 16 W, we can support powering this device
through KAD706 channel 6 or KAD704 channel 4.
Wire Tesng Standards
●
When there are mulple cores in one parallel line, only one
pair of closed cores are allowed to transmit signal. It is not
allowed to use mulple pair of cores in one cable to transmit
signal.
●
When using parallel lines, it is suggested to use those with
shielding layer. If dual core or
mulple core parallel lines
without shielding layer are routed, stability of signal
transmission can be
eected. You need to run a test before
installaon.
●
Impedance of twist pair in network cable are over 42 Ω/100 m,
so network cable cannot transmit enough power to indoor
staon. Network cable is not allowed to use during installaon.
●
Strong electricity and weak electricity cannot be wired in the
same route, they need to be wired separately and the distance
should be more than 0.5 meter.
Table A-1 Table A
Roun
g Path
Twiste
d Pair :
24
AWG
(0.2
mm
2
)
Twiste
d Pair :
20
AWG
(0.5
mm
2
)
Twiste
d Pair :
18AW
G (0.8
mm
2
)
Twiste
d Pair :
16AW
G (1
mm
2
)
Parallel
lines
(0.5
mm
2
to 0.8
mm
2
)
DS-
KAD70
6-S-DS-
KAD70
6
Transm
ission
Distanc
e ≤ 60
m
Transm
ission
Distanc
e ≤ 60
m
Transm
ission
Distanc
e ≤ 60
m
Transm
ission
Distanc
e ≤ 50
m
Transm
ission
Distanc
e ≤ 35
m
DS-
KAD70
6-DS-
KAD70
6
Transm
ission
Distanc
e ≤ 60
m
Transm
ission
Distanc
e ≤ 60
m
Transm
ission
Distanc
e ≤ 60
m
Transm
ission
Distanc
e ≤ 50
m
Transm
ission
Distanc
e ≤ 35
m
DS-
KAD70
Transm
ission
Distanc
Transm
ission
Distanc
Transm
ission
Distanc
Transm
ission
Distanc
Transm
ission
Distanc
86