Hill-Rom Advanta P1600 Service Manual

Hill-Rom Advanta P1600
429 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE MANUAL
Advanta™
Bed
From Hill-Rom
For Parts or Technical Assistance man168ra
USA (800) 445-3720 Canada (800) 267-2337
International: Contact your distributor.
Product No. P1600
errata 
man168ra-e1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hill-Rom Advanta P1600 and is the answer not in the manual?

Hill-Rom Advanta P1600 Specifications

General IconGeneral
BrandHill-Rom
ModelAdvanta P1600
CategoryMedical Equipment
LanguageEnglish

Summary

Chapter 1 Introduction

CPR Release Mechanism

Describes the CPR Release function for quickly lowering the head section in emergencies.

Specifications

Electrical Description of the Advanta Bed

Details the electrical power system's insulation, testing, supply cord, and UL approval.

General Operation

Siderail and Footboard Control Panel Overview

Details the bed controls located on head end siderails and the footboard control panel.

Optional Controls: Nurse Call System

Details how to activate the nurse call feature and the associated indicators.

Optional Controls: Patient Position Monitor (PPM)

Explains the integrated PPM system for patient motion monitoring, modes, and settings.

PPM Modes of Operation

Details the four modes of operation for the PPM system: Position, Exiting, Out of Bed, and Off.

Advanta Bed Scale Operation

Details the Advanta Bed scale's accuracy, range, display, and control switches.

Advanta Bed Indicator Lights and Meanings

Explains the function of various indicator lights on the footboard control panel and siderails.

Safety Tips

Service and Maintenance Safety Precautions

Provides safety guidelines for working with the bed in high positions and during service.

Chapter 2 Troubleshooting Procedures

Getting Started with Troubleshooting

Outlines the procedure for troubleshooting, starting with initial actions and function checks.

Function Checks for Subsystem Troubleshooting

Guides through mechanical, electrical, and pneumatic subsystem checks to identify malfunctions.

Service Required LED Error Codes

Explains how the Service Required LED flashes indicate specific faults and directs to troubleshooting tables.

Footboard Control Panel Switch/LED Test

Details a test procedure to check the operation of footboard control panel switches and LEDs.

Air System Self-Diagnostic Test Procedure

Describes a self-diagnostic test for the air system's drive circuitry, valves, and pump.

Air System Independent Diagnostic Test

Outlines an independent diagnostic test for the air system's relays, valves, and pump.

Troubleshooting: Head Hilow Does Not Lower

Provides steps to diagnose and resolve issues when the head section hilow function does not lower.

Troubleshooting: Foot Hilow Does Not Lower

Guides through troubleshooting steps when the foot section hilow function does not lower.

Troubleshooting: Head Hilow Does Not Go Up

Details steps for diagnosing and resolving issues when the head section hilow function does not go up.

Troubleshooting: Foot Hilow Does Not Go Up

Provides steps to diagnose and resolve issues when the foot section hilow function does not go up.

Troubleshooting: Knee Section Does Not Lower

Guides through troubleshooting steps when the knee section does not lower.

Troubleshooting: Knee Section Does Not Go Up

Details steps for diagnosing and resolving issues when the knee section does not go up.

Troubleshooting: Head Section Does Not Lower

Provides steps to diagnose and resolve issues when the head section does not lower.

Troubleshooting: Head Section Does Not Go Up

Details steps for diagnosing and resolving issues when the head section does not go up.

Troubleshooting: Head (Hilow) Not Lowering with Trendelenburg

Addresses issues when the head (hilow) section does not lower during Trendelenburg activation.

Troubleshooting: Head (Hilow) Not Raising with Reverse Trendelenburg

Addresses issues when the head (hilow) section does not raise during Reverse Trendelenburg activation.

Troubleshooting: Foot (Hilow) Not Lowering with Reverse Trendelenburg

Addresses issues when the foot (hilow) section does not lower during Reverse Trendelenburg activation.

Troubleshooting: Foot (Hilow) Not Raising with Trendelenburg

Addresses issues when the foot (hilow) section does not raise during Trendelenburg activation.

Troubleshooting: Night Light Does Not Operate

Guides through diagnosing and resolving issues with the night light not functioning.

Troubleshooting: ZoneAire® Sleep Surface Slow Leak (Error Code 2-1)

Provides steps to diagnose and fix slow air leaks in the ZoneAire® Sleep Surface system.

Troubleshooting: ZoneAire® Continuous Run (Error Code 2-2)

Guides through diagnosing and fixing continuous run errors in the ZoneAire® Sleep Surface system.

Troubleshooting: ZoneAire® Triac Short (Error Code 2-3)

Addresses issues related to a triac short error in the ZoneAire® Sleep Surface system.

Troubleshooting: ZoneAire® Sensor EEPROM Error (Error Code 2-4)

Guides through diagnosing and fixing ZoneAire® Sensor EEPROM errors.

Troubleshooting: ZoneAire® Mattress Disconnected (Error Code 2-5)

Provides steps to diagnose and fix errors related to disconnected ZoneAire® Sleep Surface mattresses.

Troubleshooting: ZoneAire® Triac Open (Error Code 2-6)

Guides through diagnosing and fixing ZoneAire® Triac Open errors.

Troubleshooting: ZoneAire® LON Communication Error (Error Code 2-7)

Details steps to diagnose and resolve ZoneAire® LON communication errors.

Troubleshooting: Key Stuck Closed (Error Code 1-2)

Provides steps to diagnose and fix issues where a key is stuck in a closed position.

Troubleshooting: ZoneAire® Sleep Surface Does Not Work

Guides through troubleshooting steps when the ZoneAire® Sleep Surface is not functioning.

Troubleshooting: Scale Display Errors (Err0-Err3)

Details how to diagnose and resolve errors displayed on the bed scale.

Troubleshooting: Patient Position Monitor (PPM) Not Functioning

Provides steps to diagnose and fix issues when the Patient Position Monitor (PPM) is not functioning.

Troubleshooting: PPM System Beeps Twice and Flashes LEDs

Guides through diagnosing and resolving issues where the PPM system beeps and flashes LEDs.

Troubleshooting: SideCom® Communication System Tester

Explains how to use the SideCom® tester to check siderail communication system functions.

Chapter 3 Theory of Operation

Logic Control P.C. Board (P/N 63285) Operation

Explains the logic control board's role as the heart of the articulation system and its inputs/outputs.

Power Supply P.C. Board (P/N 63349) Functionality

Describes the power supply system's subassemblies, safety features, and regulator circuits.

Patient Position Monitor (PPM) System Theory

Explains the PPM system's power supply, piezo speaker, watchdog timer, and force sensing resistors.

Chapter 4 Removal, Replacement, and Adjustment Procedures

Air Sleep Surface Mattress Removal and Replacement

Explains how to remove and install the ZoneAire® Sleep Surface mattress.

Air Sleep Surface Sensor Control P.C. Board

Provides instructions for removing and replacing the sensor control P.C. board.

Head Limit Switch Removal, Replacement, and Adjustment

Details the procedures for removing, replacing, and adjusting the head limit switch.

Hilow Head Limit Switch Procedures

Explains the removal, replacement, and adjustment of the hilow head limit switch.

Knee Limit Switch Removal, Replacement, and Adjustment

Details the procedures for removing, replacing, and adjusting the knee limit switch.

CPR Release Handle Adjustment Procedure

Explains how to adjust the CPR release handle for proper cable operation.

CPR Limit Switch Removal and Replacement

Provides instructions for removing and replacing the CPR limit switch.

Hilow Foot Limit Switch Removal and Replacement

Explains the procedures for removing and replacing the hilow foot limit switch.

Patient Position Monitor (PPM) Sensor Procedures

Explains how to remove and replace the Patient Position Monitor (PPM) sensor.

Chapter 5 Parts List

Chapter 6 General Procedures

Scale Calibration Procedure

Provides steps for calibrating the bed scale using specific weights and button sequences.

Preventive Maintenance

Recommends annual preventive maintenance (PM) for ensuring operative life and minimizing downtime.

Advanta Bed Preventive Maintenance Schedule

Provides a schedule of functions and procedures for regular preventive maintenance.

Advanta Bed Preventive Maintenance Checklist

Offers a checklist to document and track preventive maintenance activities and costs.

ZoneAire® Sleep Surface Preventive Maintenance

Recommends preventive maintenance for the ZoneAire® Sleep Surface to ensure long operative life.