SJ100 Dynamic Braking Selection Chart
SJ100 Series Internal Dynamic Braking Table
Voltage
Class
Model Number Motor hp
Braking
Unit
Braking
Torque @
60 Hz
(without
external
resistor)
(%)
External
Resistance
(Ω)
Braking
Torque @
60 Hz
(%)
Minimum
Resistance
(Ω)
Braking
Torque @
60 Hz
(%)
Maximum
Braking
Duty
Cycle
(%)
SJ100-002NFU/E 1/4 Built-in 50 180 150 100 200 10 150
SJ100-004NFU/E 1/2 Built-in 50 180 150 100 200 10 150
SJ100-005NFE 3/4 Built-in 50 180 150 100 200 10 150
SJ100-007NFU/E 1 Built-in 50 100 150 35 200 10 150
SJ100-011NFE 1.5 Built-in 50 50 150 35 200 10 150
SJ100-015NFU/E 2 Built-in 50 50 150 35 200 10 100
SJ100-022NFU/E 3 Built-in 20 50 100 35 150 10 100
SJ100-037LFU 5 Built-in 20 35 100 35 100 10 100
SJ100-055LFU 7.5 Built-in 20 17 80 17 80 10 50
SJ100-075LFU 10 Built-in 20 17 80 17 80 10 50
SJ100-004HFU/E 1/2 Built-in 50 180 150 180 150 10 500
SJ100-007HFU/E 1 Built-in 50 180 150 180 150 10 300
SJ100-015HFU/E 2 Built-in 50 180 150 180 150 10 300
SJ100-022HFU/E 3 Built-in 20 100 100 100 100 10 300
SJ100-030HFE 4 Built-in 20 100 100 100 100 10 200
SJ100-040HFU/E 5 Built-in 20 100 100 100 100 10 200
SJ100-055HFU/E 7.5 Built-in 20 70 80 70 80 10 200
SJ100-075HFU/E 10 Built-in 20 70 80 70 80 10 150
Minimum
Resistance
@ 100%
Braking
Duty Cycle
(Ω)
200 V
400 V
1/4 to10 hp (0.2 to 7.5 kW)
Using Internal
Resistor
Using Optional
External Resistor
Performance @ Minimum
Resistance