3 Capacity and selection data
YUTAKI M
TCGB0123 rev.2 - 10/2019
62
3.3 YUTAKI M
3.3.1 Maximum heating capacity table (kW) (Integrated)
Ambient temperature (ºC WB)
-20 -15 -10 -7 -2 2 7 12 15 20 25
System
Water
outlet
temp
(ºC)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
RASM-2VRE
60 3.20 2.29 3.64 2.25 4.00 2.22 5.00 2.17 5.50 1.77 5.66 1.71 5.93 1.61 6.20 1.51
55 4.00 2.42 4.20 2.27 4.48 2.25 4.70 2.24 6.00 2.22 6.30 1.80 6.46 1.68 6.73 1.48 7.00 1.27
50 4.36 2.32 4.60 2.22 4.85 2.13 5.05 2.05 6.15 2.01 6.65 1.71 6.85 1.61 7.17 1.43 7.50 1.25
45 4.00 2.35 4.25 2.30 4.72 2.22 5.00 2.17 5.22 2.00 5.40 1.86 6.30 1.80 7.00 1.63 7.23 1.54 7.62 1.38 8.00 1.23
40 4.15 2.34 4.54 2.24 4.93 2.14 5.17 2.08 5.32 1.86 5.45 1.70 6.40 1.59 7.25 1.48 7.48 1.42 7.87 1.31 8.25 1.21
35 4.30 2.32 4.50 2.14 5.02 2.04 5.33 1.98 5.42 1.73 5.49 1.53 6.50 1.38 7.50 1.34 7.73 1.30 8.12 1.24 8.50 1.18
30 4.50 2.23 4.80 2.09 5.31 1.93 5.62 1.83 5.69 1.65 5.75 1.50 6.70 1.34 7.75 1.30 7.98 1.27 8.37 1.20 8.75 1.14
25 4.70 2.14 5.10 2.04 5.60 1.82 5.90 1.68 5.95 1.56 6.00 1.46 6.90 1.30 8.00 1.27 8.23 1.23 8.62 1.16 9.00 1.09
20 4.90 2.04 5.40 1.99 5.89 1.71 6.18 1.54 6.22 1.48 6.25 1.43 7.10 1.26 8.25 1.24 8.48 1.19 8.87 1.12 9.25 1.05
RASM-3VRE
60 5.10 3.64 5.77 3.46 6.31 3.32 7.50 3.21 8.00 2.76 8.12 2.73 8.31 2.70 8.50 2.66
55 5.30 3.53 5.50 3.44 6.42 3.42 7.15 3.40 9.00 3.30 9.80 3.11 9.85 3.07 9.92 3.01 10.00 2.94
50 5.80 3.39 6.08 3.31 6.83 3.24 7.43 3.18
9.15 3.08 9.90 2.91 10.03 2.88 10.24
2.83 10.45 2.78
45 5.25 3.39 5.70 3.35 6.30 3.24 6.67 3.18 7.24 3.06 7.70 2.96
9.30 2.86 10.00 2.70 10.21 2.68 10.55
2.66 10.90 2.63
40 5.63 3.36 6.19 3.27 6.75 3.17 7.08 3.12 7.64 2.96 8.09 2.83
10.15 2.77 10.75 2.60 10.88 2.59 11.09
2.56 11.30 2.53
35 6.00 3.33 6.25 3.29 7.03 3.14 7.50 3.06 8.04 2.85 8.47 2.69
10.99 2.68 11.50 2.50 11.55 2.49 11.62
2.46 11.70 2.44
30 6.25 3.29 6.52 3.23 7.23 3.08 7.65 3.00 8.36 2.77 8.94 2.58
11.15 2.57 11.65 2.32 11.70 2.30 11.77
2.26 11.85 2.22
25 6.50 3.25 6.80 3.16 7.42 3.02 7.80 2.94 8.69 2.68 9.40 2.48
11.30 2.46 11.80 2.15 11.85 2.11 11.92
2.06 12.00 2.00
20 6.75 3.21 7.08 3.10 7.62 2.97 7.94 2.88 9.09 2.62
10.00
2.40
11.50 2.40 12.00 2.00 12.16 1.97 12.43
1.92 12.70 1.87
? NOTE
CAP: Capacity at maximum compressor frequency (kW). Capacity is valid for difference between water inlet and water outlet of 3-8 ºC.
IPT: Total input power (kW)
The table above shows the input power (IPT) at maximum capacity (CAP). Most of the time, the unit runs at partial load, so that the actual
input is lower.

Table of Contents

Other manuals for Hitachi YUTAKI S Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi YUTAKI S Series and is the answer not in the manual?

Hitachi YUTAKI S Series Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
RefrigerantR410A
Cooling Capacity2.5 - 16 kW
Operating Temperature Range (Cooling)46°C
Indoor Unit DimensionsVaries by model
Outdoor Unit DimensionsVaries by model
Noise LevelVaries by model

Related product manuals