5 - 6
Interfunction Delay
An interfunction delay of up to 5000 milliseconds (in 5ms increments) may
be placed between the transmission of each segment of the message
string. Scan the Interfunction Delay bar code below, then scan the num-
ber of 5ms delays, and the Save bar code using the Programming Chart
inside the back cover of this manual.
To remove this delay, scan the Interfunction Delay bar code, then set the
number of delays to 0. Scan the Save bar code using the Programming
Chart inside the back cover of this manual.
Intermessage Delay
An intermessage delay of up to 5000 milliseconds (in 5ms increments)
may be placed between each scan transmission. Scan the Intermessage
Delay bar code below, then scan the number of 5ms delays, and the Save
bar code using the Programming Chart inside the back cover of this man-
ual.
To remove this delay, scan the Intermessage Delay bar code, then set the
number of delays to 0. Scan the Save bar code using the Programming
Chart inside the back cover of this manual.
Interfunction Delays
Prefix Scanned Data Suffix
1 2345STX HT CR LF
Interfunction Delay
2nd Scan Transmission1st Scan Transmission
Intermessage Delay
Intermessage Delay

Table of Contents

Other manuals for Honeywell 1900GSR-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 1900GSR-2 and is the answer not in the manual?

Honeywell 1900GSR-2 Specifications

General IconGeneral
BrandHoneywell
Model1900GSR-2
CategoryBarcode Reader
LanguageEnglish

Related product manuals